Safety interlock and vent system to alleviate potentially dangerous ice blockage of top-loading cryostat sample sticks
- 22 June 2013
- journal article
- other
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 46 (4) , 1236-1239
Abstract
A combined solution is presented for minimizing the safety hazards associated with closed cycle cryostats described by Swainson & Cranswick [J. Appl. Cryst.(2010),43, 206–210]. The initial solution is to install a vent tube with one open end deep inside the sample space and a pressure relief valve at the top. This solution works for either a cryogen or a cryogen-free (closed cycle) system. The second approach, which can be combined with the first and is applicable to cryogen-free cryostats, involves electrically interlocking the closed cycle refrigerator compressor to the sample space, so that the system cannot be cooled in the presence of a leak path to air.Keywords
This publication has 3 references indexed in Scilit:
- Safety considerations with top-loading cryostats, involving `icing-up' of the sample space with solid airJournal of Applied Crystallography, 2009
- Brittle Fracture of Ice at 77 KJournal of Glaciology, 1975
- Measurements concerning the vapour-liquid equilibrum of solutions of He3 in He4 below 2.19°KPhysica, 1949