A handheld platform for target protein detection and quantification using disposable nanopore strips
Open Access
- 4 October 2018
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-12
Abstract
Accessible point-of-care technologies that can provide immunoassay and molecular modalities could dramatically enhance diagnostics, particularly for infectious disease control in low-resource settings. Solid-state nanopores are simple and durable sensors with low-energy instrumentation requirements. While nanopore sensors have demonstrated efficacy for nucleic acid targets, selective detection and quantification of target proteins from sample background has not been demonstrated. We present a simple approach for electronic detection and quantification of target proteins that combines novel biomolecular engineering methods, a portable reader device and disposable nanopore test strips. The target of interest can be varied by swapping the binding domain on our engineered detection reagent, which eficiently binds in the bulk-phase to the target and subsequently generates a unique signature when passing through the pore. We show modularity of the detection reagent for two HIV antibodies, TNFα and tetanus toxin as targets. A saliva swab-to-result is demonstrated for clinically relevant HIV antibody levels (0.4–20 mg/liter) in under 60 seconds. While other strip-like assays are qualitative, the presented method is quantitative and sets the stage for simultaneous immunoassay and molecular diagnostic functionality within a single portable platform.Keywords
Funding Information
- U.S. Department of Health & Human Services | NIH | National Institute of Biomedical Imaging and Bioengineering (1R43EB022518, 1R43EB022518, 1R43EB022518)
- Two Pore Guys, Inc.
This publication has 39 references indexed in Scilit:
- A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function TestingScience Translational Medicine, 2012
- EIS microfluidic chips for flow immunoassay and ultrasensitive cholera toxin detectionLab on a Chip, 2010
- Single-molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrationsNature Biotechnology, 2010
- Label-free biomarker detection from whole bloodNature Nanotechnology, 2009
- Integrated barcode chips for rapid, multiplexed analysis of proteins in microliter quantities of bloodNature Biotechnology, 2008
- Requirements for high impact diagnostics in the developing worldNature, 2006
- Design of immunogens that present the crown of the HIV-1 V3 loop in a conformation competent to generate 447-52D-like antibodiesBiochemical Journal, 2006
- Detection Limits for Nanoscale BiosensorsNano Letters, 2005
- Combined Triplex/Duplex Invasion of Double-Stranded DNA by “Tail-Clamp” Peptide Nucleic AcidBiochemistry, 2003
- Detection of antibody to HIV in saliva: a brief reviewClinical and Diagnostic Virology, 1994