Study design: Retrospective comparative cohort study. Introduction: Accurate pedicle screw placement is critical for spinal stability and for preventing neurological or vascular injury. This study compared screw-placement accuracy and safety between robot-assisted and navigation-guided pedicle screw implantation and explored differences between intraoperative 3D-fluoroscopy and preoperative CT-based surface-matching registration. Methods: We assessed all consecutive patients who underwent robot-assisted or navigation-guided pedicle screw placement at our department between 2018 and 2022. For robot-assisted placement, screw trajectories were planned on preoperative CT, and intraoperative patient registration was performed using two radiographs fused with a preoperative CT. Navigation-guided placement used either intraoperative 3D-fluoroscopy registration in the final prone position or CT-based surface matching using preoperative supine CT images. Screw positions were evaluated on postoperative CT using a standardised ordinal grading scale from 0 to 4, with Grades 3–4 defined as clinically relevant malpositions. We analysed accuracy using generalised estimating equations with patient-level clustering and adjustment for covariates. We also assessed operative time, radiation exposure, complications, and revision rates. Results: We analysed 1,718 pedicle screws from 268 patients: 728 were robot-assisted and 990 navigation-guided, including 579 using 3D-fluoroscopy and 411 using CT-based surface matching. Mean screw grades were 0.956 for robot-assisted placement, 0.864 for navigation overall, 0.807 for 3D-fluoroscopy, and 0.944 for surface matching. After accounting for patient clustering and adjustment, screw grade did not differ significantly between navigation-guided and robot-assisted placement (aOR 0.87, 95% CI 0.50–1.53; p = 0.632). Grade 3–4 malpositions occurred in 11.7% of robot-assisted and 9.4% of navigation-guided screws, with no significant difference after adjustment. Radiation exposure and fluoroscopy time differed significantly between groups ( p < 0.001), with the lowest median values for robot-assisted placement, followed by surface matching and 3D-fluoroscopy. Registration failure occurred in 12/118 (10.2%) robot-assisted patients compared with 2/150 (1.3%) navigation-guided patients. One new postoperative neurological deficit (foot drop) occurred in the robot-assisted group and none in the navigation group. Conclusions: No significant overall difference in screw-placement accuracy was demonstrated between the two platforms (Robot vs. navigation) or registration modalities in this heterogeneous real-world cohort; however, they showed different operational profiles, particularly concerning intraoperative radiation exposure, fluoroscopy time, and registration failure.Keywords
This publication has 14 references indexed in Scilit:
- Level-specific comparison of 3D navigated and robotic arm-guided screw placement: an accuracy assessment of 1210 pedicle screws in lumbar surgeryThe Spine Journal, 2024
- Automatic image registration on intraoperative CBCT compared to Surface Matching registration on preoperative CT for spinal navigation: accuracy and workflowInternational Journal of Computer Assisted Radiology and Surgery, 2024
- Image Quality and Dose Comparison of 3 Mobile Intraoperative Three-Dimensional Imaging Systems in Spine SurgeryWorld Neurosurgery, 2022
- Diagnostic reference levels and median doses for common clinical indications of CT: findings from an international registryEuropean Radiology, 2021
- Accuracy of Current Techniques for Placement of Pedicle Screws in the Spine: A Comprehensive Systematic Review and Meta-Analysis of 51,161 ScrewsWorld Neurosurgery, 2019
- Accuracy of Pedicle Screw Insertion Among 3 Image-Guided Navigation Systems: Systematic Review and Meta-AnalysisWorld Neurosurgery, 2018
- Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniquesEuropean Spine Journal, 2011
- Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placementEuropean Spine Journal, 2011
- Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studiesEuropean Spine Journal, 2010
- Image-guided pedicle screw insertion accuracy: a meta-analysisInternational Orthopaedics, 2009