A Tripolar Spatiotemporal Stimulator With Return-Electrode-Based Charge-Pack Injection Technique for Charge Imbalance Correction
- 3 November 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 61 (3) , 1068-1081
Abstract
Spatiotemporal stimulation (STS) has emerged as a novel method for multi-channel neural electrical stimulation but suffers from severe crosstalk. The crosstalk includes electric field distribution and current distribution, which affect spatial resolution and charge balance, respectively. Compared with monopolar stimulation, bipolar stimulation exhibits less electric field distribution, making it more suitable for STS. However, an offset voltage on charge imbalance occurs in traditional bipolar stimulation under STS due to the current distribution. This article first analyzes the causes and effects of offset voltage in two traditional bipolar stimulation configurations and quantitatively compares the results under experimental measurement. To simultaneously achieve high spatial resolution stimulation and precise charge balancing (CB) for bipolar stimulation, we propose a four-channel tripolar spatiotemporal stimulator with a return-electrode-based charge-pack injection (RECPI) technique. By introducing a return electrode (RE), the residual voltages on both working and counter electrodes (CEs) can be effectively compensated. The stimulator is fabricated in a 180-nm standard CMOS process, with a core area of 1.209 mm2 and each stimulation channel occupying 0.256 mm2. It achieves a voltage compliance of ±10.4 V and a maximum stimulation current of 2.8 mA. Electrical and in vitro tests demonstrate that with RECPI, residual voltage on each electrode and offset voltage of each channel are compensated within ±7.5 mV after CB. Furthermore, in vivo tests validate the functionality of the tripolar stimulator.Keywords
Funding Information
- National Natural Science Foundation of China (62371332)
- National Key Research and Development Program of China (2024YFE0203500)
This publication has 46 references indexed in Scilit:
- A 10V Compliant 16-Channel Stimulator ASIC with sub-10nA Mismatch and Simultaneous ETI Sensing for Selective Vagus Nerve Stimulation2024
- Walking naturally after spinal cord injury using a brain–spine interfaceNature, 2023
- Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind HumansCell, 2020
- A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communicationNature Biomedical Engineering, 2020
- Targeted neurotechnology restores walking in humans with spinal cord injuryNature, 2018
- A pulse-width-adaptive active charge balancing circuit with pulse-insertion based residual charge compensation and quantization for electrical stimulation applications2015
- Reducing current spread using current focusing in cochlear implant usersHearing Research, 2012
- Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implantsJournal of Neural Engineering, 2011
- A CMOS retinal neurostimulator capable of focussed, simultaneous stimulationJournal of Neural Engineering, 2009
- Electrical stimulation of excitable tissue: design of efficacious and safe protocolsJournal of Neuroscience Methods, 2005