Charge balancing PV System using charge-pumped flyback-boost-forward converter including differential power processor
Authors:
- 1 May 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 356-360
Abstract
This paper proposes a differential power processor using charge-pumped flyback-boost-forward converter including a function of charge balancing for PV System. This converter operates a boost converter and forward converter independently even with the transformer coupling. In the normal operation when the multiple loads have a power balancing, it has a high efficiency without the flyback operation. If the loads have imbalance among them, the charge-pumped flyback converter starts to operate for the output-capacitor charge balancing. This converter is cost-effective due to the unified transformer shared by the forward, boost and the flyback converters. Also, perspective of the MPPT efficiency, the forward converter operates as the differential power processor for the distributed MPPT control. Furthermore, since the forward converter is not fed by the boost output but by the coaxial coupled-inductor (transformer) of the boost, the power conversion efficiency is improved. An experimental verification from the 143-W hardware prototype is presented.Keywords
This publication has 4 references indexed in Scilit:
- Power Conditioning for a Small-Scale PV System with Charge-Balancing Integrated Micro-InverterJournal of Power Electronics, 2015
- Differential Power Processing for Increased Energy Production and Reliability of Photovoltaic SystemsIEEE Transactions on Power Electronics, 2013
- High Efficiency Step-Down Flyback Converter Using Coaxial Cable Coupled-InductorJournal of Power Electronics, 2013
- Variable DC-Link Voltage Algorithm with a Wide Range of Maximum Power Point Tracking for a Two-String PV SystemEnergies, 2013