Nonrigid motion correction in 3D using autofocusing withlocalized linear translations
Open Access
- 3 February 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (6) , 1785-1797
Abstract
MR scans are sensitive to motion effects due to the scan duration. To properly suppress artifacts from nonrigid body motion, complex models with elements such as translation, rotation, shear, and scaling have been incorporated into the reconstruction pipeline. However, these techniques are computationally intensive and difficult to implement for online reconstruction. On a sufficiently small spatial scale, the different types of motion can be well approximated as simple linear translations. This formulation allows for a practical autofocusing algorithm that locally minimizes a given motion metric — more specifically, the proposed localized gradient‐entropy metric. To reduce the vast search space for an optimal solution, possible motion paths are limited to the motion measured from multichannel navigator data. The novel navigation strategy is based on the so‐called “Butterfly” navigators, which are modifications of the spin‐warp sequence that provides intrinsic translational motion information with negligible overhead. With a 32‐channel abdominal coil, sufficient number of motion measurements were found to approximate possible linear motion paths for every image voxel. The correction scheme was applied to free‐breathing abdominal patient studies. In these scans, a reduction in artifacts from complex, nonrigid motion was observed. Magn Reson Med, 2012.Keywords
This publication has 55 references indexed in Scilit:
- Hierarchical adaptive local affine registration for fast and robust respiratory motion estimationMedical Image Analysis, 2011
- Compressed‐sensing motion compensation (CosMo): A joint prospective–retrospective respiratory navigator for coronary MRIMagnetic Resonance in Medicine, 2011
- Nonrigid retrospective respiratory motion correction in whole‐heart coronary MRAMagnetic Resonance in Medicine, 2011
- Echo‐planar imaging with prospective slice‐by‐slice motion correction using active markersMagnetic Resonance in Medicine, 2011
- Real‐time motion correction for high‐resolution larynx imagingMagnetic Resonance in Medicine, 2011
- Intrinsic detection of motion in segmented sequencesMagnetic Resonance in Medicine, 2010
- PROMO: Real‐time prospective motion correction in MRI using image‐based trackingMagnetic Resonance in Medicine, 2009
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Orbital navigator echoes for motion measurements in magnetic resonance imagingMagnetic Resonance in Medicine, 1995
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991