Urine as a Specimen to Diagnose Infections in Twenty-First Century: Focus on Analytical Accuracy
Open Access
- 1 January 2012
- journal article
- review article
- Published by Frontiers Media SA in Frontiers in Immunology
- Vol. 3, 19925
Abstract
Urine as a clinical specimen to diagnose infections has been used since ancient times. Many rapid technologies to assist diagnosis of infections are currently in use. Alongside traditional enzyme immunoassays (EIA), new technologies have emerged. Molecular analysis of transrenal DNA to diagnose infections is also a rapidly growing field. The majority of EIAs utilize the detection of excreted sugar compounds of the outer microbial cell-wall shed into the bloodstream and excreted into the urine. This mini-review focuses on current knowledge on rapid urinary antigen detection tests to diagnose most common infections, and highlights their diagnostic utility. The past and the future of urinalysis are also briefly discussed. The analysis of the literature shows that some methods are not quantitative, and analytical sensitivity may remain suboptimal. In addition, the performance criteria and technical documentation of some commercial tests are insufficient. Clinical microbiologists and physicians should be alert to assay limitations.Keywords
This publication has 56 references indexed in Scilit:
- Diagnosing tuberculosis with urine lipoarabinomannan: systematic review and meta-analysisEuropean Respiratory Journal, 2011
- Mycoplasma genitalium: An Emerging Cause of Sexually Transmitted Disease in WomenPLOS Pathogens, 2011
- Histoplasma Antigen Clearance during Treatment of Histoplasmosis in Patients with AIDS Determined by a Quantitative Antigen Enzyme ImmunoassayClinical and Vaccine Immunology, 2011
- IP-10 detection in urine is associated with lung diseasesBMC Infectious Diseases, 2010
- Screening of Urine Samples by Flow Cytometry Reduces the Need for CultureJournal of Clinical Microbiology, 2010
- Detection of dengue virus in saliva and urine by real time RT-PCRVirology Journal, 2010
- Variable viral clearance despite adequate ganciclovir plasma levels during valganciclovir treatment for cytomegalovirus disease in D+/R- transplant recipientsBMC Infectious Diseases, 2010
- Detection of Coccidioides Antigenemia following Dissociation of Immune ComplexesClinical and Vaccine Immunology, 2009
- Development and Evaluation of an Enzyme-Linked Immunosorbent Assay To DetectHistoplasma capsulatumAntigenuria in Immunocompromised PatientsClinical and Vaccine Immunology, 2009
- Detection of Histoplasma Antigen by a Quantitative Enzyme ImmunoassayClinical and Vaccine Immunology, 2007