Optimization of a New Mass Spectrometry Method for Measurement of Breast Milk Iodine Concentrations and an Assessment of the Effect of Analytic Method and Timing of Within-Feed Sample Collection on Breast Milk Iodine Concentrations
- 1 February 2016
- journal article
- research article
- Published by SAGE Publications in Thyroid®
- Vol. 26 (2) , 287-295
Abstract
Background: Breast milk iodine concentration (BMIC) may be an indicator of iodine status during lactation, but there are few data comparing different analytical methods or timing of sampling. The aims of this study were: (i) to optimize a new inductively coupled plasma mass spectrometry (ICP-MS) method; and (ii) to evaluate the effect of analytical method and timing of within-feed sample collection on BMIC. Methods: The colorimetric Sandell–Kolthoff method was evaluated with (a) or without (b) alkaline ashing, and ICP-MS was evaluated using a new 129 I isotope ratio approach including Tellurium (Te) for mass bias correction (c) or external standard curve (d). From iodine-sufficient lactating women ( n = 97), three samples were collected within one breast-feeding session (fore-, mid-, and hind-feed samples) and BMIC was analyzed using (c) and (d). Results: Iodine recovery from NIST SRM1549a whole milk powder for methods (a)–(d) was 67%, 24%, 105%, and 102%, respectively. Intra- and inter-assay coefficients of variation for ICP-MS comparing (c) and (d) were 1.3% versus 5.6% ( p = 0.04) and 1.1% versus 2.4% ( p = 0.33). The limit of detection (LOD) was lower for (c) (0.26 μg/kg) than it was for (d) (2.54 μg/kg; p = 0.02). Using (c), the median [95% confidence interval (CI) obtained by bootstrap] BMIC (μg/kg) in foremilk (179 [CI 161–206]) and in mid-feed milk (184 [CI 160–220]) were not significantly different ( p = 0.017), but were higher than in hindmilk (175 [CI 153–216]; p < 0.001). In foremilk using (d), BMIC was 199 ([CI 182–257]; p < 0.001 vs. (c)). The variation in BMIC comparing (c) and (d) (13%) was greater than variation within feeding (5%; p < 0.001). Conclusions: Because of poor recoveries, (a) and (b) should not be used to measure BMIC. Compared with (d), (c) has the advantages of higher precision and a lower LOD. In iodine-sufficient women, BMIC shows low variation within a breast-feeding session, so timing of sampling is not a major determinant of BMIC.Keywords
This publication has 37 references indexed in Scilit:
- Iodine Insufficiency: A Global Health Problem?Advances in Nutrition, 2013
- Iodine and Mental Development of Children 5 Years Old and Under: A Systematic Review and Meta-AnalysisNutrients, 2013
- Review of analytical methods for the quantification of iodine in complex matricesAnalytica Chimica Acta, 2011
- Trace iodine quantitation in biological samples by mass spectrometric methodsTalanta, 2009
- Breastfeeding and maternal and infant iodine nutritionClinical Endocrinology, 2009
- Determination of iodine in human milk and infant formulasJournal of Trace Elements in Medicine and Biology, 2007
- A high accuracy primary ratio method for the determination of iodine in complex matrices by double isotope dilution using MC-ICPMS and 129I spikeJournal of Analytical Atomic Spectrometry, 2006
- Determination of iodine in food samples by inductively coupled plasma mass spectrometry after alkaline extractionJournal of Analytical Atomic Spectrometry, 1998
- Iodine content of infant formulas and iodine intake of premature babies: high risk of iodine deficiency.Archives of Disease in Childhood - Fetal and Neonatal Edition, 1994
- Improved routine method for the determination of total iodine in urine and milkThe Analyst, 1986