Textile Electromagnetic Coupler for Monitoring Vital Signs and Changes in Lung Water Content
Authors:
- 9 September 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 14 (15361225) , 151-154
Abstract
A newly designed and fabricated textile electromagnetic (EM) coupler and a novel side-by-side transmission coefficient measurement arrangement were found most suitable for clinical trial and practical implementation of a microwave-based system for monitoring vital signs and measuring changes in lung water content. Comparative simulation studies were conducted to determine the effect of the textile material's conductivity on the sensitivity and accuracy of the new side-by-side S21 measurement arrangement. Two sewing techniques were examined to develop a robust and stable textile EM coupler prototype with a secured feeding structure. The new textile EM couplers and measurement procedure are tested in human clinical studies. Results were benchmarked with an FDA-approved medical device and confirmed the readiness of the developed textile EM coupler and new side-by-side transmission coefficient measurement arrangement for clinical trials and the ultimate practical realization of this microwave technology. Specifically, it is shown that the embroidered steel thread textile EM coupler is best suited for practical implementation and provided high sensitivity to detect vital signs and a 1% change of lung water.Keywords
This publication has 10 references indexed in Scilit:
- Microwave Stethoscope: Development and Benchmarking of a Vital Signs Sensor Using Computer-Controlled Phantoms and Human StudiesIEEE Transactions on Biomedical Engineering, 2013
- Microwave Stethoscope, a new noninvasive multiple vital signs sensor: Human clinical trials2012
- Wideband EM coupler/applicator design and characterization for the clinical benchmarking tests of microwave stethoscope (MiSt)2012
- A survey on wearable biosensor systems for health monitoring2008
- Design and Characterization of Purely Textile Patch AntennasIEEE Transactions on Advanced Packaging, 2006
- The measurement of lung waterCritical Care, 1999
- Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies.1996
- A microwave method for estimating absolute value of average lung waterRadio Science, 1982
- Electromagnetic techniques for medical diagnosis: A reviewProceedings of the IEEE, 1980
- Microwave Reflection and Transmission Measurements for Pulmonary Diagnosis and MonitoringIEEE Transactions on Biomedical Engineering, 1978