Incomplete stent apposition in Enterprise stent–mediated coiling of aneurysms: persistence over time and risk of delayed ischemic events
Authors:
- 1 May 2013
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 118 (5) , 1014-1022
Abstract
Object: Incomplete stent apposition of the closed cell–design Enterprise stent following stent-mediated coil embolization of intracranial aneurysms has been associated with increased risk of periprocedural thromboembolic events. In this study, the authors seek to determine the natural history of incomplete stent apposition and evaluate the clinical implications of the phenomenon. Methods: Since January 2009, all patients receiving Enterprise stents in the treatment of intracranial aneurysms at the authors' institution have undergone serial 3-T MRI with incomplete stent apposition identified by the crescent sign on multiplanar reconstructions of MR angiograms. Magnetic resonance images and MR angiograms obtained at 3, 9, and 18 months after stent-assisted coil embolization were analyzed along with admission and follow-up clinical medical records. These records were evaluated for any radiographic and clinical, transient or permanent ischemic neurological events. Results: Fifty patients receiving Enterprise stents were eligible for inclusion and analysis in the study. Incomplete stent apposition was identified in postoperative imaging studies in 22 (44%) of 50 patients, with 19 (86%) of 22 crescent signs persisting and 3 (14%) of 22 crescent signs resolving on subsequent serial imaging. Delayed ischemic events occurred in 8 (16%) of 50 cases, and all cases involved patients with incomplete stent apposition. The events were transient ischemic attacks (TIAs) in 5 cases, asymptomatic radiographic strokes in 2 cases, and symptomatic strokes and TIAs in the final case. There were no delayed ischemic events in patients who did not have incomplete stent apposition. Only 1 of the delayed ischemic events (2%) was permanent and symptomatic. The postoperative presence of a crescent sign and persistence of the crescent sign were both significantly associated with delayed ischemic events (p < 0.001 and p = 0.002, respectively). Conclusions: Incomplete stent apposition is a temporally persistent phenomenon, which resolves spontaneously in only a small minority of cases and appears to be a risk factor for delayed ischemic events. Although further follow-up is needed, these results suggest that longer duration of antiplatelet therapy and clinical follow-up may be warranted in cases of recognized incomplete stent apposition.Keywords
This publication has 29 references indexed in Scilit:
- Stent-Assisted Coiling of Intracranial Bifurcation Aneurysms Leads to Immediate and Delayed Intracranial Vascular Angle RemodelingAmerican Journal of Neuroradiology, 2011
- Parent Vessel Size and Curvature Strongly Influence Risk of Incomplete Stent Apposition in Enterprise Intracranial Aneurysm Stent CoilingAmerican Journal of Neuroradiology, 2011
- Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting StentsCirculation, 2011
- A single center comparison of coiling versus stent assisted coiling in 90 consecutive paraophthalmic region aneurysmsJournal of NeuroInterventional Surgery, 2011
- Delivery technique plays an important role in determining vessel wall apposition of the Enterprise self-expanding intracranial stentJournal of NeuroInterventional Surgery, 2011
- Possible Mechanisms for Delayed Migration of the Closed Cell—Designed Enterprise Stent When Used in the Adjunctive Treatment of a Basilar Artery AneurysmAmerican Journal of Neuroradiology, 2010
- Proximal migration and compaction of an Enterprise stent into a coiled basilar apex aneurysm: a posterior circulation phenomenon?Journal of NeuroInterventional Surgery, 2010
- Neuroform stent assisted aneurysm treatment: evolving treatment strategies, complications and results of long term follow-upJournal of NeuroInterventional Surgery, 2009
- NEUROFORM STENT-ASSISTED COIL EMBOLIZATION OF WIDE-NECK INTRACRANIAL ANEURYSMSNeurosurgery, 2007
- Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent ImplantationCirculation, 2007