Efficacy of radiation attenuating caps in reducing radiation doses received at the cerebral level in interventional physicians: a systematic review
- 15 July 2024
- journal article
- review article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (3) , 031001
Abstract
Background. Anecdotal reports are appearing in the scientific literature about cases of brain tumors in interventional physicians who are exposed to ionizing radiation. In response to this alarm, several designs of leaded caps have been made commercially available. However, the results reported on their efficacy are discordant. Objective. To synthesize, by means of a systematic review of the literature, the capacity of decreasing radiation levels conferred by radiation attenuating devices (RADs) at the cerebral level of interventional physicians. Methodology. A systematic review was performed including the following databases: MEDLINE, SCOPUS, EBSCO, Science Direct, Cochrane Controlled Trials Register (CENTRAL), WOS, WHO International Clinical Trials Register, Scielo and Google Scholar, considering original studies that evaluated the efficacy of RAD in experimental or clinical contexts from January 1990 to May 2023. Data selection and extraction were performed in triplicate, with a fourth author resolving discrepancies. Results. Twenty articles were included in the review from a total of 373 studies initially selected from the databases. From these, twelve studies were performed under clinical conditions encompassing 3801 fluoroscopically guided procedures, ten studies were performed under experimental conditions with phantoms, with a total of 88 procedures, four studies were performed using numerical calculations with a total of 63 procedures. The attenuation and effectiveness of provided by the caps analyzed in the present review varying from 12.3% to 99.9%, and 4.9% to 91% respectively. Conclusion. RAD were found to potentially provide radiation protection, but a high heterogeneity in the shielding afforded was found. This indicates the need for local assessment of cap efficiency according to the practice.Keywords
This publication has 36 references indexed in Scilit:
- Effectiveness of staff radiation protection devices for interventional cardiology proceduresPhysica Medica, 2023
- Estimating radiation exposure of the brain of a physician with a protective flap in interventional radiology: A phantom studyJournal of Applied Clinical Medical Physics, 2022
- Effectiveness of Radiation Protection Caps for Lowering dose to the Brain and the Eye LensesCardioVascular and Interventional Radiology, 2021
- Efficiency of the RADPAD Surgical Cap in Reducing Brain Exposure During Pacemaker and Defibrillator ImplantationJACC: Clinical Electrophysiology, 2021
- Head and Neck Radiation Dose and Radiation Safety for Interventional PhysiciansJACC: Cardiovascular Interventions, 2017
- A Review of Radiation Protection Solutions for the Staff in the Cardiac Catheterisation LaboratoryHeart, Lung and Circulation, 2016
- Invasive Cardiologists Are Exposed to Greater Left Sided Cranial RadiationJACC: Cardiovascular Interventions, 2015
- Brain and Neck Tumors Among Physicians Performing Interventional ProceduresThe American Journal of Cardiology, 2013
- Effective Use of Radiation Shields to Minimize Operator Dose During Invasive Cardiology ProceduresJACC: Cardiovascular Interventions, 2011
- Clinical and epidemiologic characteristics of first primary tumors of the central nervous system and related organs among atomic bomb survivors in Hiroshima and Nagasaki, 1958–1995Cancer, 2004