Characterization of Biosensors Based on Recombinant Glutamate Oxidase: Comparison of Crosslinking Agents in Terms of Enzyme Loading and Efficiency Parameters
Open Access
Abstract
Amperometric l-glutamate (Glu) biosensors, based on both wild-type and a recombinant form of l-glutamate oxidase (GluOx), were designed and characterized in terms of enzyme-kinetic, sensitivity and stability parameters in attempts to fabricate a real-time Glu monitoring device suitable for future long-term detection of this amino acid in biological and other complex media. A comparison of the enzyme from these two sources showed that they were similar in terms of biosensor performance. Optimization of the loading of the polycationic stabilization agent, polyethyleneimine (PEI), was established before investigating a range of crosslinking agents under different conditions: glutaraldehyde (GA), polyethylene glycol (PEG), and polyethylene glycol diglycidyl ether (PEGDE). Whereas PEI-free biosensor designs lost most of their meager Glu sensitivity after one or two days, configurations with a 2:5 ratio of dip-evaporation applications of PEI(1%):GluOx(400 U/mL) displayed a 20-fold increase in their initial sensitivity, and a decay half-life extended to 10 days. All the crosslinkers studied had no effect on initial Glu sensitivity, but enhanced biosensor stability, provided the crosslinking procedure was carried out under well-defined conditions. The resulting biosensor design based on the recombinant enzyme deposited on a permselective layer of poly-(ortho-phenylenediamine), PoPD/PEI2/GluOx5/PEGDE, displayed good sensitivity (LOD < 0.2 μM), response time (t90% < 1 s) and stability over a 90-day period, making it an attractive candidate for future long-term monitoring of Glu concentration dynamics in complex media.Keywords
This publication has 91 references indexed in Scilit:
- Further In-vitro Characterization of an Implantable Biosensor for Ethanol Monitoring in the BrainSensors, 2013
- Highly selective and stable microdisc biosensors for l-glutamate monitoringSensors and Actuators B: Chemical, 2013
- Immobilization Method to Preserve Enzyme Specificity in Biosensors: Consequences for Brain Glutamate DetectionAnalytical Chemistry, 2013
- Effect of Dexamethasone on Gliosis, Ischemia, and Dopamine Extraction during Microdialysis Sampling in Brain TissueAnalytical Chemistry, 2011
- Chronic microsensors for longitudinal, subsecond dopamine detection in behaving animalsNature Methods, 2009
- Histological studies of the effects of chronic implantation of ceramic-based microelectrode arrays and microdialysis probes in rat prefrontal cortexBrain Research, 2009
- Extracellular Glutamate Concentration in Hippocampal SliceThe Journal of Neuroscience, 2007
- Duration of Glutamate Release After Acute Ischemic StrokeStroke, 1997
- Intracerebral microdialysis of glutamate after aneurysmal subarachnoid hemorrhageIntensive Care Medicine, 1996
- Intracerebral Microdialysis of Glutamate and Aspartate Two Vascular Territories after Aneurysmal Subarachnoid HemorrhageNeurosurgery, 1996