A study on design, development, optimization and validation of product development framework for humidifier chamber
Authors:
- 17 February 2023
- journal article
- research article
- Published by Springer Nature in International Journal on Interactive Design and Manufacturing (IJIDeM)
- Vol. 17 (4) , 1677-1691
Abstract
The upper airways of the patients under Mechanical Ventilation (MV) cannot humidify the inspired air by themselves, while heat and moisture exchange remain the most important criteria. Insufficient humidification leads to multiple issues while humidifiers, the devices used to add water molecules, gas and temperature, are used in MVs. There is a need exists to develop a new humidifier that can achieve 99% humidity, cost-effective, adheres to ISO standards and compact with controlled design. The aim of the current study is to develop an optimized product development framework for designing the humidifier chamber and to define the product testing guidelines for verification and validation of the humidification chamber. By following a step-wise methodology, the researchers compared the existing samples in the market, conducted CFD analysis for optimization, developed the prototype and framed the guidelines for testing and validation of the humidification chamber. The study found the optimum specifications given herewith as per the outcomes; Inlet/Outlet (mm) should be 22 M, Compressible volume should be 300 ml, Maximum water capacity should be 130 ml while maximum peak flow should be 180 L/min. Further, the resistance to flow should be 10 cm of H2O and the diameter of chassis should be 120 mm. With the humidification chamber being made up of PP, PVC, Silicone and AL, the optimum weight of the chamber should be 125.6 g.Keywords
This publication has 27 references indexed in Scilit:
- A novel control strategy to improve the performances of heated wire humidifiers in artificial neonatal ventilationPhysiological Measurement, 2012
- Humidification During Invasive and Noninvasive Mechanical Ventilation: 2012Respiratory Care, 2012
- Comparison of a novel humidifier with two conventional humidifiers during high-frequency oscillatory ventilationCritical Care, 2009
- Charakteristik mehrerer Befeuchter für die CPAP- sowie invasive und nicht invasive Beatmungstherapie und Sauerstofflangzeittherapie unter standardisierten Bedingungen in einer KlimakammerPneumologie, 2008
- Mouth Breathing Compromises Adherence to Nasal Continuous Positive Airway Pressure TherapyChest, 2004
- The Effect of Inlet Gas Temperatures on Heated Humidifier PerformanceJournal of Aerosol Medicine, 2002
- Performance of Heated Humidifiers with a Heated Wire According to Ventilatory SettingsJournal of Aerosol Medicine, 2001
- The Effect of Heated Wire Circuits on Humidification of Inspired GasesAnesthesia & Analgesia, 1994
- Effect of dry and humidified gases on the respiratory epithelium in rabbitsJournal of Pediatric Surgery, 1975
- The Influence of Varying Air Humidity on Mucociliary ActivityActa Oto-Laryngologica, 1975