Research on the Efficiency of Composite Beam Application in Multi-Storey Buildings
Open Access
- 10 October 2020
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 12 (20) , 8328
Abstract
Over the past decade, several types of composite slim floor constructions have been used in multi-storey buildings in Lithuania. In order to study the efficiency of composite beam application in steel-framed multi-storey buildings, Thorbeam (A1), Deltabeam (A2), slim floor beam (A3) and asymmetric slim floor beam (A4) were chosen and evaluated according to nine assessment criteria (beam cost (K1), initial preparation on site (K2), installation time (K3), complexity of installation technology (K4), labour costs (K5), fire resistance (K6), load bearing capacity (K7), beam versatility (K8), and availability of beams (K9)). First, the significance of the rating criteria was selected and the order of the ranking criteria was obtained (K1˃K7˃K3˃K6˃K4˃K5˃K2˃K8˃K9) by means of a survey questionnaire. Second, the beams were ranked according to the points given by the questionnaire respondents as follows: 160 points were given to A2, 144 points to A1, 129 points to A4, and 111 points to A3. Deltabeam is considered to be the most rational alternative of the four beams compared. Calculations done using the Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS) analysis method revealed that composite beam A2 was the best slim floor structure alternative for an eight-storey high-rise commercial residential building frame, A1 ranked second, A4 ranked third, and A3 ranked fourth. In addition, the four composite beams were compared to a reinforced concrete beam (A5) according to three assessment criteria (beam cost including installation (C1), beam self-weight (C2) and fire resistance (C3)). Deltabeam was found to be efficient for use as a slim floor structure in a multi-story building due to having the lowest cost, including installation, and self-weight, and the highest fire resistance compared to other composite beams studied. Although Deltabeams are 1.4 times more expensive than reinforced concrete beams, including installation costs, they save about 2.5% of the building’s height compared to reinforced concrete beams.Keywords
This publication has 24 references indexed in Scilit:
- Effect of dowel shear connector on performance of slim-floor composite shear beamsJournal of Constructional Steel Research, 2020
- Flexural behaviour of composite slim floor beamsStructures, 2019
- The evolution of composite flooring systems: applications, testing, modelling and eurocode design approachesJournal of Constructional Steel Research, 2019
- Service and Ultimate Behaviour of Slim Floor Beams: An Experimental StudyStructures, 2019
- Ultimate strength of a beam-to-column joint in a composite slim floor frameJournal of Constructional Steel Research, 2018
- Numerical procedure for nonlinear behavior analysis of composite slim floor beamsJournal of Constructional Steel Research, 2015
- Loading capacity of composite slim frame beamsJournal of Constructional Steel Research, 2009
- On materially and geometrically non-linear analysis of reinforced concrete planar framesInternational Journal of Solids and Structures, 2004
- Composite beams and floor systems fully integrated with building servicesProgress in Structural Engineering and Materials, 2002
- The behaviour of asymmetric slim floor steel beams in fireJournal of Constructional Steel Research, 1999