Shaking Table Tests of a Novel Flat Slab-Flanged Wall (FSFW) Coupled System with Embedded Concrete-Filled-Steel-Tubes in Wall Piers
Open Access
- 13 September 2022
- Vol. 12 (9) , 1441
Abstract
The flat slab-flanged wall (FSFW) coupled system has gained popularity in recent years; however, its seismic performance remains an issue, as beams and columns in it are commonly eliminated. To tackle this problem, embedding concrete-filled steel tubes (CFSTs) in wall piers has been proposed to strengthen the system; the viability of this approach has been verified at the member level. Along this line, this study embarks on a shaking table testing of a 1/8-scale five-story FSFW structure equipped with CFSTs in walls, with an aim to understand the overall seismic behavior of such an enhanced system. As with the practice in many countries, the plan layout of the test structure consisted of four rows of wall piers, thus presenting a ‘fish-bone’ floor configuration that relied only upon the walls to resist gravity and lateral loads. The structure was subjected to a suite of input ground motions along with white-noise excitations. By so doing, its damage progression, pattern and dynamic characteristics were clearly identified. Furthermore, a non-linear time history analysis was conducted using PERFORM-3D, and the goodness-of-fit of the computed responses to the experimental records was examined. Findings indicated that the application of CFSTs was instrumental in resisting the simulated earthquake loads acting on the FSFW system, hence the global response limits required by codes of practice were met, even in the case of extremely strong earthquakes. Nevertheless, the junction between the shear walls and floor slabs was found to be the weakest links in the whole system. Designers are thus cautioned to implement proper detailing in those regions to prevent local distress, though it did not appear to acutely impair the system’s collapse-resisting capacity.Keywords
Funding Information
- Guangdong Provincial Key Laboratory of Modern Civil Engineering Technology, South China University of Technology (2021B1212040003)
- Architectural Design & Research Institute of SCUT Co. Ltd. (2017-001)
This publication has 39 references indexed in Scilit:
- Finite element modelling of concrete-filled steel stub columns under axial compressionJournal of Constructional Steel Research, 2013
- Shake-Table Test of a Full-Scale 7-Story Building Slice. Phase I: Rectangular WallJournal of Structural Engineering, 2011
- Analytically derived fragility relationships for the modern high‐rise buildings in the UAEThe Structural Design of Tall and Special Buildings, 2010
- Practical modelling of high‐rise dual systems with reinforced concrete slab‐column framesThe Structural Design of Tall and Special Buildings, 2009
- Modelling issues for tall reinforced concrete core wall buildingsThe Structural Design of Tall and Special Buildings, 2007
- Shaking table model test on Shanghai World Financial Center TowerEarthquake Engineering & Structural Dynamics, 2006
- Three-Dimensional Effects on Openings of Laterally Loaded Pierced Shear WallsJournal of Structural Engineering, 2004
- Fragility analysis of flat-slab structuresEngineering Structures, 2004
- SIMPLE PUSH-OVER ANALYSIS OF ASYMMETRIC BUILDINGSEarthquake Engineering & Structural Dynamics, 1997
- Stresses in Slabs Coupling Flanged Shear WallsJournal of Structural Engineering, 1984