The Isometric Horizontal Push Test: Test–Retest Reliability and Validation Study
Authors:
- Antonio Dello IaconoAIAntonio Dello Iacono
- Stephanie ValentinSVStephanie Valentin
- Mark SandersonMSMark Sanderson
- Israel HalperinIHIsrael Halperin
- 1 April 2020
- journal article
- research article
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. 15 (4) , 581-584
Abstract
Purpose: To investigate the test–retest reliability and criterion validity of the isometric horizontal push test (IHPT), a newly designed test that selectively measures the horizontal component of maximal isometric force. Methods: Twenty-four active males with ≥3 years of resistance training experience performed 2 testing sessions of the IHPT, separated by 3 to 4 days of rest. In each session, subjects performed 3 maximal trials of the IHPT with 3 minutes of rest between them. The peak force outputs were collected simultaneously using a strain gauge and the criterion equipment consisting of a floor-embedded force plate. Results: The test–retest reliability of peak force values was nearly perfect (intraclass correlation coefficient = ∼.99). Bland–Altman analysis showed excellent agreement between days with nearly no bias for strain gauge 1.2 N (95% confidence interval [CI], −3 to 6 N) and force plate 0.8 N (95% CI, −4 to 6 N). A nearly perfect correlation was observed between the strain gauge and force plate (r = .98, P < .001), with a small bias of 8 N (95% CI, 1.2 to 15 N) in favor of the force plate. The sensitivity of the IHPT was also good, with smallest worthwhile change greater than standard error of measurement for both the strain gauge (smallest worthwhile change: 29 N; standard error of measurement: 17 N; 95% CI, 14 to 20 N) and the force plate (smallest worthwhile change: 29 N; standard error of measurement: 18 N; 95% CI, 14 to 19 N) devices. Conclusions: The high degree of validity, reliability, and sensitivity of the IHPT, coupled with its affordability, portability, ease of use, and time efficacy, point to the potential of the test for assessment and monitoring purposes.Keywords
This publication has 11 references indexed in Scilit:
- Standardization and Methodological Considerations for the Isometric Midthigh PullStrength & Conditioning Journal, 2019
- Validity of an Isometric Midthigh Pull Dynamometer in Male Youth AthletesJournal of Strength & Conditioning Research, 2018
- Validity and Reliability of a Portable Isometric Mid-Thigh Clean PullJournal of Strength & Conditioning Research, 2017
- Isometric Mid-Thigh Pull Correlates With Strength, Sprint, and Agility Performance in Collegiate Rugby Union PlayersJournal of Strength & Conditioning Research, 2016
- Acute Effects of Drop-Jump Protocols on Explosive Performances of Elite Handball PlayersJournal of Strength & Conditioning Research, 2016
- Effect of Sampling Frequency on Isometric Midthigh-Pull KineticsInternational Journal of Sports Physiology and Performance, 2016
- Acceleration capability in elite sprinters and ground impulse: Push more, brake less?Journal of Biomechanics, 2015
- Relationships Between Ground Reaction Impulse and Sprint Acceleration Performance in Team Sport AthletesJournal of Strength & Conditioning Research, 2013
- Explosive force production during isometric squats correlates with athletic performance in rugby union playersJournal of Sports Sciences, 2013
- AN INVESTIGATION OF RUGBY SCRUMMAGING POSTURE AND INDIVIDUAL MAXIMUM PUSHING FORCEJournal of Strength & Conditioning Research, 2007