Clinical Use of Continuous Glucose Monitoring in Critically Ill Pediatric Patients with Diabetic Ketoacidosis
Open Access
- 31 July 2023
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 25 (8) , 529-537
Abstract
Background: The use of continuous glucose monitoring (CGM) in pediatric patients with diabetic ketoacidosis (DKA) remains investigational, and data on its accuracy in pediatric intensive care units (PICU) are limited. This study evaluated the accuracy of three CGM devices in pediatric patients with DKA in the PICU. Methods: We compared 399 matched pairs of CGM and point-of-care capillary glucose (POC) values and grouped patients based on whether they changed their CGM sensor during their PICU stay. Results: Eighteen patients with a mean age of 10.98 ± 4.20 years were included, with three patients in the sensor change group. The overall mean absolute relative difference (MARD) was 13.02%. The Medtronic Guardian Sensor 3 ( n = 331), Dexcom G6 ( n = 41), and Abbott FreeStyle Libre 1 ( n = 27) showed MARD values of 13.40%, 11.12%, and 11.33%, respectively. The surveillance error grid (SEG), Bland–Altman plot, and Pearson's correlation coefficient demonstrated satisfactory clinical accuracy of the CGM devices (SEG zones A and B, 98.5%; mean difference, 15.5 mg/dL; Pearson's correlation coefficient [ r 2 ], 0.76, P < 0.0001). MARD was significantly lower in subjects who did not experience a sensor change (11.74% vs. 17.31%, P = 0.048). Also, a statistically significant negative correlation was found between serum bicarbonate levels and POC–CGM values ( r = −0.34, P < 0.001). Conclusions: The severity of DKA has a major effect on reducing the accuracy of the CGM, especially during the first several days in the intensive care unit. The reduced accuracy appears to be related to acidosis, as reflected in the serum bicarbonate levels.Keywords
This publication has 32 references indexed in Scilit:
- Time Delay of CGM SensorsJournal of Diabetes Science and Technology, 2015
- Understanding Bland Altman analysisBiochemia Medica, 2015
- The Surveillance Error GridJournal of Diabetes Science and Technology, 2014
- Accuracy of a continuous glucose monitoring system in dogs and cats with diabetic ketoacidosisJournal of Veterinary Emergency and Critical Care, 2010
- Pilot evaluation of continuous subcutaneous glucose monitoring in children with multiple organ dysfunction syndromePediatric Critical Care Medicine, 2009
- New Equations to Estimate GFR in Children with CKDJournal of the American Society of Nephrology, 2009
- Diabetic Ketoacidosis in the Pediatric ICUPediatric Clinics of North America, 2008
- Performance of the continuous glucose monitoring system (CGMS) during development of ketosis in patients on insulin pump therapyDiabetic Medicine, 2006
- Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac SurgeryPediatrics, 2006
- European Society for Paediatric Endocrinology/Lawson Wilkins Pediatric Endocrine Society Consensus Statement on Diabetic Ketoacidosis in Children and AdolescentsPediatrics, 2004