The diagnostic value of grey-scale inversion technique in chest radiography
Open Access
- 18 January 2022
- journal article
- research article
- Published by Springer Nature in La radiologia medica
- Vol. 127 (3) , 294-304
Abstract
Purpose We investigated whether the additional use of grey-scale inversion technique improves the interpretation of eight chest abnormalities, in terms of diagnostic performance and interobserver variability. Material and methods A total of 507 patients who underwent a chest computed tomography (CT) examination and a chest radiography (CXR) within 24 h were enrolled. CT was the standard of reference. Images were retrospectively reviewed for the presence of atelectasis, consolidation, interstitial abnormality, nodule, mass, pleural effusion, pneumothorax and rib fractures. Four CXR reading settings, involving 3 readers were organized: only standard; only inverted; standard followed by inverted; and inverted followed by standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy, assessed with the area under the curve (AUC), and their 95% confidence interval were calculated for each reader and setting. Interobserver agreement was tested by Cohen’s K test with quadratic weights (Kw) and its 95%CI. Results CXR sensitivity % for any finding was 35.1 (95% CI: 33 to 37) for setting 1, 35.9 (95% CI: 33 to 37), for setting 2, 32.59 (95% CI: 30 to 34) for setting 3, and 35.56 (95% CI: 33 to 37) for setting 4; specificity % 93.78 (95% CI: 91 to 95), 93.92 (95% CI: 91 to 95), 94.43 (95% CI: 92 to 96), 93.86 (95% CI: 91 to 95); PPV % 56.22 (95% CI: 54.2 to 58.2), 56.49 (95% CI: 54.5 to 58.5), 57.15 (95% CI: 55 to 59), 56.75 (95% CI: 54 to 58); NPV % 85.66 (95% CI: 83 to 87), 85.74 (95% CI: 83 to 87), 85.29 (95% CI: 83 to 87), 85.73 (95% CI: 83 to 87); AUC values 0.64 (95% CI: 0.62 to 0.66), 0.65 (95% CI: 0.63 to 0.67), 0.64 (95% CI: 0.62 to 0.66), 0.65 (95% CI: 0.63 to 0.67); Kw values 0.42 (95% CI: 0.4 to 0.44), 0.40 (95% CI: 0.38 to 0.42), 0.42 (95% CI: 0.4 to 0.44), 0.41 (95% CI: 0.39 to 0.43) for settings 1, 2, 3 and 4, respectively. Conclusions No significant advantages were observed in the use of grey-scale inversion technique neither over standard display mode nor in combination at the detection of eight chest abnormalities.Keywords
This publication has 30 references indexed in Scilit:
- Standard versus inverted digital luminescence radiography in detecting pulmonary nodules: A ROC analysisEuropean Journal of Radiology, 2013
- Grey-scale inversion improves detection of lung nodulesBritish Journal of Radiology, 2013
- Gray-scale inversion radiographic display for the detection of pulmonary nodules on chest radiographsClinical Imaging, 2012
- Observer training for computer-aided detection of pulmonary nodules in chest radiographyEuropean Radiology, 2012
- Gray-Scale Reversal for the Detection of Pulmonary Nodules on a PACS WorkstationAmerican Journal of Roentgenology, 2011
- Computer-aided diagnosis in chest radiography: Beyond nodulesEuropean Journal of Radiology, 2009
- Dual Energy Subtraction and Temporal Subtraction Chest RadiographyJournal of Thoracic Imaging, 2008
- Digital chest radiography: an update on modern technology, dose containment and control of image qualityEuropean Radiology, 2008
- Fleischner Society: Glossary of Terms for Thoracic ImagingRadiology, 2008
- The diagnosis of pulmonary nodules: comparison between standard and inverse digitized images and conventional chest radiographsAmerican Journal of Roentgenology, 1989