The Use of a Wax Bite Wafer and a Double Computed Tomography Scan Procedure to Obtain a Three-Dimensional Augmented Virtual Skull Model
Authors:
- Gwen R. J. SwennenGSGwen R. J. Swennen
- Maurice Y. MommaertsMMMaurice Y. Mommaerts
- Johan AbeloosJAJohan Abeloos
- Calix De ClercqCCCalix De Clercq
- Philippe LamoralPLPhilippe Lamoral
- Nathalie NeytNNNathalie Neyt
- Jan CasselmanJCJan Casselman
- Filip SchutyserFSFilip Schutyser
- 1 May 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 18 (3) , 533-539
Abstract
A detailed visualization of the interocclusal relationship is essential in a three-dimensional virtual planning setup for orthognathic and facial orthomorphic surgery. The purpose of this study was to introduce and evaluate the use of a wax bite wafer in combination with a double computed tomography (CT) scan procedure to augment the three-dimensional virtual model of the skull with a detailed dental surface. A total of 10 orthognathic patients were scanned after a standardized multislice CT scanning protocol with dose reduction with their wax bite wafer in place. Afterward, the impressions of the upper and lower arches and the wax bite wafer were scanned for each patient separately using a high-resolution standardized multislice CT scanning protocol. Accurate fitting of the virtual impressions on the wax bite wafer was done with surface matching using iterative closest points. Consecutively, automatic rigid point-based registration of the wax bite wafer on the patient scan was performed to implement the digital virtual dental arches into the patient's skull model (Maxilim, version 2.0; Medicim NV, St-Niklaas, Belgium). Probability error histograms showed errors of ≤0.16 mm (25% percentile), ≤0.31 mm (50% percentile), and ≤0.92 (90% percentile) for iterative closest point surface matching. The mean registration error for automatic point-based registration was 0.17 ± 0.07 mm (range, 0.12-0.22 mm). The combination of the wax bite wafer with the double CT scan procedure allowed for the setup of an accurate three-dimensional virtual augmented model of the skull with detailed dental surface. However, from a clinical workload, data handling, and computational point of view, this method is too time-consuming to be introduced in the clinical routine.Keywords
This publication has 15 references indexed in Scilit:
- The use of a new 3D splint and double CT scan procedure to obtain an accurate anatomic virtual augmented model of the skullInternational Journal of Oral and Maxillofacial Surgery, 2007
- Three-dimensional cephalometry: Spiral multi-slice vs cone-beam computed tomographyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Robust Visualization of the Dental Occlusion by a Double Scan Procedure2005
- Fusion of computed tomography data and optical 3D images of the dentition for streak artefact correction in the simulation of orthognathic surgeryDentomaxillofacial Radiology, 2004
- Radiation absorbed in maxillofacial imaging with a new dental computed tomography deviceOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2003
- A new technique for the creation of a computerized composite skull modelJournal of Oral and Maxillofacial Surgery, 2003
- The graz hemisphere splint: a new precise, non-invasive method of replacing the dental arch of 3D-models by plaster modelsJournal of Cranio-Maxillofacial Surgery, 1998
- Dental arch transfer procedure into three-dimensional laser technology models (LTM)Journal of Cranio-Maxillofacial Surgery, 1996
- Three-dimensional craniofacial surgery: transfer from a three-dimensional model (Endoplan) to clinical surgery: a new technique (Graz)Journal of Cranio-Maxillofacial Surgery, 1992
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992