Abstract
The kinetics of β2-microglobulin during hemodialysis and hemodiafiltration is well described by a two-compartment model where clearance by the dialyzer is from a central compartment volume that approximates plasma volume and a total distribution volume that approximates extracellular fluid volume. The kinetics of middle molecules with molecular weights larger than β2-microglobulin have not been extensively studied. Intradialytic plasma concentrations and overall dialyzer clearances of β2-microglobulin (11.8 kD), myoglobin (16.7 kD) and complement factor D (24.4 kD) were used to estimate three kinetic parameters from a two-compartment model, namely intercompartmental clearance, central compartment volume and total distribution volume, in hemodialysis patients; these data were collected during two clinical trials of medium cut-off dialyzers (with extended middle molecule removal) during hemodialysis and high-flux dialyzers during hemodialysis and hemodiafiltration. In the current exploratory analyses, the kinetic parameters from all dialyzers were combined. Overall dialyzer clearance was evaluated by total mass removed in the dialysate. In total, 345 sets of kinetic parameters from 35 patients were determined. Intercompartmental clearance and central compartment volume for myoglobin and complement factor D were smaller (P < 0.001) than those for β2-microglobulin. Independent of middle molecule, intercompartmental clearance and central compartment volume were associated with overall dialyzer clearance (P < 0.001), but total distribution volume was not (P = 0.083). A two-compartment kinetic model can only describe intradialytic kinetics of middle molecules with molecular weights larger than β2-microglobulin if the central compartment is small and dependent on overall dialyzer clearance.Keywords
Funding Information
- Baxter Healthcare
This publication has 37 references indexed in Scilit:
- Kinetic modelling of haemodialysis removal of myoglobin in rhabdomyolysis patientsComputer Methods and Programs in Biomedicine, 2014
- Online haemodiafiltration: definition, dose quantification and safety revisitedNephrology Dialysis Transplantation, 2013
- Kinetic Model of Phosphorus Mobilization during and after Short and Conventional HemodialysisClinical Journal of the American Society of Nephrology, 2011
- A Regional Blood Flow Model for β2-Microglobulin Kinetics and for Simulating Intra-dialytic Exercise EffectAnnals of Biomedical Engineering, 2011
- Reduction in Protein-Bound Solutes Unacceptable as Marker of Dialysis Efficacy during Alternate-Night Nocturnal HemodialysisAmerican Journal of Nephrology, 2011
- Effect of increasing dialysate flow rate on diffusive mass transfer of urea, phosphate and 2-microglobulin during clinical haemodialysisNephrology Dialysis Transplantation, 2010
- Downloadable computer models for renal replacement therapyKidney International, 2006
- Review on uremic toxins: Classification, concentration, and interindividual variabilityKidney International, 2003
- Quest for postdialysis urea rebound-equilibrated Kt/V with only intradialytic urea samplesKidney International, 1999
- An estimate of β2-microglobulin deposition rate in uremic patients on hemodialysis using a mathematical kinetic modelKidney International, 1995