Characterization of high density SiPM non-linearity and energy resolution for prompt gamma imaging applications
- 1 July 2017
- journal article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (07) , P07001
Abstract
Fondazione Bruno Kessler (FBK) (Trento, Italy) has recently introduced High Density (HD) and Ultra High-Density (UHD) SiPMs, featuring very small micro-cell pitch. The high cell density is a very important factor to improve the linearity of the SiPM in high-dynamic-range applications, such as the scintillation light readout in high-energy gamma-ray spectroscopy and in prompt gamma imaging for proton therapy. The energy resolution at high energies is a trade-off between the excess noise factor caused by the non-linearity of the SiPM and the photon detection efficiency of the detector. To study these effects, we developed a new setup that simulates the LYSO light emission in response to gamma photons up to 30 MeV, using a pulsed light source. We measured the non-linearity and energy resolution vs. energy of the FBK RGB-HD e RGB-UHD SiPM technologies. We considered five different cell sizes, ranging from 10 μm up to 25 μm. With the UHD technology we were able to observe a remarkable reduction of the SiPM non-linearity, less than 5% at 5 MeV with 10 μm cells, which should be compared to a non-linearity of 50% with 25 μm-cell HD-SiPMs. With the same setup, we also measured the different components of the energy resolution (intrinsic, statistical, detector and electronic noise) vs. cell size, over-voltage and energy and we separated the different sources of excess noise factor.Keywords
This publication has 13 references indexed in Scilit:
- Study of the photo-detection efficiency of FBK High-Density silicon photomultipliersJournal of Instrumentation, 2016
- Set-up and methods for SiPM Photo-Detection Efficiency measurementsJournal of Instrumentation, 2016
- State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMsJournal of Instrumentation, 2016
- Performance of a 64-channel, 3.2×3.2 cm2 SiPM tile for TOF-PET applicationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Effects of very high radiation on SiPMsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Prompt gamma imaging of proton pencil beams at clinical dose ratePhysics in Medicine & Biology, 2014
- Performance of FBK high-density SiPM technology coupled to Ce:LYSO and Ce:GAGG for TOF-PETPhysics in Medicine & Biology, 2014
- Characterization of new FBK SiPM technology for visible light detectionJournal of Instrumentation, 2013
- Radiation damage studies of silicon photomultipliersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- Geiger-mode avalanche photodiodes, history, properties and problemsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006