Bayesian strain-rate correction applied to dynamic CPTu data

Authors:

Abstract
In situ free fall penetration tests (FFP) are performed for cable routes development due to their cost and efficient way to geotechnical characterize near-surface marine sediments. FFP readings differs from quasi-static observations due the higher impact velocity and nonlinear penetration rate of the cone probe. Therefore, application of FFP observations to geotechnical parameters estimation requires a strain-rate correction according to some strain-rate laws. The commonly employed procedure requires matched (i.e., closely located in space and time) quasi-static and FFP measurements, therefore losing the cost and time efficiency of FFP tests. This work illustrates a Bayesian methodology for FFP cone resistance correction from limited unmatched quasi-static CPTU readings. Three different stain-rate laws are exploited in order to assess the most plausible data conversion. The methodology is applied to the port of Nice (France), where in situ investigations are available from previous studies.