Novel harvesting technique of no-touch saphenous vein graft using THUNDERBEAT
- 28 February 2019
- journal article
- research article
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 67 (7) , 650-652
Abstract
The no-touch technique of saphenous vein involves harvesting the vein as a pedicled graft and avoidance of direct contact with the vein or excessive high-pressure expansion. This technique provides long-term graft patency as that of internal mammary artery; however, the wound complications could be greater than conventional skeletonized technique. To solve the problem of leg wound trouble and to harvest the vein simpler, we have developed a novel harvesting technique using a newly developed energy device, THUNDERBEAT. This technique has the ability of efficacious tissue dissection, safer sealing of branches, and less wound complications without thermal damage to the graft. This strategy was successfully used in 35 patients.Keywords
This publication has 6 references indexed in Scilit:
- Proximal first: a beneficial strategy for no-touch saphenous vein graftInteractive CardioVascular and Thoracic Surgery, 2018
- Simple and safe removal modification of the HEARTSTRING deviceEuropean Journal of Cardio-Thoracic Surgery, 2017
- The no-touch saphenous vein for coronary artery bypass grafting maintains a patency, after 16 years, comparable to the left internal thoracic artery: A randomized trialThe Journal of Thoracic and Cardiovascular Surgery, 2015
- Pedicled no-touch saphenous vein graft harvest limits vascular smooth muscle cell activation: the PATENT saphenous vein graft study†European Journal of Cardio-Thoracic Surgery, 2013
- Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instrumentsSurgical Endoscopy, 2012
- A New No-Touch Preparation Technique:Technical notesScandinavian Journal of Thoracic and Cardiovascular Surgery, 1996