Deflection errors due to sample potential in electron beam lithography machine
Authors:
- 1 February 1981
- journal article
- Published by IOP Publishing in Journal of Physics E: Scientific Instruments
- Vol. 14 (2) , 194-195
Abstract
When a metallic or conductive sample is held at a potential V in an electron beam lithography machine, an electric field is created between the sample and the nearest machine parts such as the holder for backscattered electron detectors. Consequently, registration accuracy deteriorates. Deflection errors divided by deflection lengths (relative deflection errors) are found to be proportional to the sample voltage. They agree quite well with the predicted values, where relative deflection error is shown to be inversely proportional to the electron beam acceleration voltage.Keywords
This publication has 2 references indexed in Scilit:
- Analysis of Trapezoid Distortion due to Charge-Up in Electron Beam RecordingJapanese Journal of Applied Physics, 1971
- Distortion of Electron-Beam-Recorded Patterns on a Photographic Plate due to Charge-UpJapanese Journal of Applied Physics, 1970