Improved Frequency Locked Loop Based Synchronization Method for Three-Phase Grid-Connected Inverter under Unbalanced and Distorted Grid Conditions
Open Access
Abstract
To quickly and accurately estimate the parameters of the fundamental positive- and negative-sequence under the unbalanced and distorted grid voltage, a synchronization method is presented in this paper. The proposed method is based on both a harmonic decoupling network consisting of multiple dual second-order generalized integrators (MDSOGIs) and an improved frequency locked loop (IFLL), so it is called the MDSOGI-IFLL. Due to the IFLL, the system has the feature that the dynamic performance of estimating the fundamental frequency is independent of the variation of both the fundamental positive- and negative-sequence voltage. In this paper, a first-order linear frequency adaption model is established for the design of the IFLL. Finally, the good performance of the proposed MDSOGI-IFLL is validated by the simulation and experiment.Keywords
Funding Information
- Natural Science Foundation of Guangdong Province (2016A030313476)
This publication has 24 references indexed in Scilit:
- An Adaptive Frequency Phase-Locked Loop Based on a Third Order Generalized IntegratorEnergies, 2019
- On Small Signal Frequency Stability under Virtual Inertia and the Role of PLLsEnergies, 2018
- An Adaptive Prefiltering Method to Improve the Speed/Accuracy Tradeoff of Voltage Sequence Detection Methods Under Adverse Grid ConditionsIEEE Transactions on Industrial Electronics, 2013
- Problems of Startup and Phase Jumps in PLL SystemsIEEE Transactions on Power Electronics, 2011
- A Novel Hardware-Based All-Digital Phase-Locked Loop Applied to Grid-Connected Power ConvertersIEEE Transactions on Industrial Electronics, 2010
- Decoupled Double Synchronous Reference Frame PLL for Power Converters ControlIEEE Transactions on Power Electronics, 2007
- Overview of Control and Grid Synchronization for Distributed Power Generation SystemsIEEE Transactions on Industrial Electronics, 2006
- Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditionsIEEE Transactions on Industry Applications, 2002
- A phase tracking system for three phase utility interface invertersIEEE Transactions on Power Electronics, 2000
- Operation of a phase locked loop system under distorted utility conditionsIEEE Transactions on Industry Applications, 1997