EEG Markers of Dementia with Lewy Bodies: A Multicenter Cohort Study

Authors:

Abstract
Quantitative EEG (QEEG) has demonstrated good discriminative capacity for dementia with Lewy bodies (DLB) diagnosis as compared to Alzheimer’s disease (AD) with a predictive value of 100% in a single cohort study. EEG in DLB was characterized by a dominant frequency (DF) in pre-alpha (5.5–7.5 Hz), theta, or delta bands and DF variability (DFV) >1.2 Hz, frequency prevalence (FP) pre-alpha in >40% and FP alpha in 20) collected from four European Centers. EEG traces from 19 scalp derivations were acquired as at least 10 min continuous signals and epoched in off-setting as series of 2-second-long epochs, subsequently processed by Fast Fourier Transform (frequency resolution 0.5 Hz). DLB patients showed EEG specific abnormalities in posterior derivations characterized by DF 50%, FP alpha 0.5 Hz. AD patients displayed stable alpha DF, DFV p < 10 –6 ), DFV ( p < 0.05), FP pre-alpha ( p < 10 –12 ) and FP alpha ( p < 10 –12 ). Discriminant analysis detected specific cut-offs for every EEG mathematical descriptor; DF = 8, DFV = 2.2 Hz, FP pre-alpha=33%, FP alpha = 41% for posterior derivations. If at least one of the cut-off values was met, the percentage of DLB and AD patients correctly classified was 90% and 64%, respectively. The findings in this multicenter study support the validity of QEEG analysis as a tool for diagnosis in DLB patients.

This publication has 39 references indexed in Scilit: