Simplified determination of commissural orientation in bicuspid aortic valves
- 30 August 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 58 (6) , 1153-1160
Abstract
OBJECTIVES: In bicuspid aortic valves (BAV), commissural orientation (CO) varies between 180° and close to 120°. Postoperative CO has a strong effect on repair durability, and different repair approaches have been proposed according to CO; it is thus important for aortic repair. A precise, simple and reproducible determination by preoperative echocardiography would facilitate intraoperative decision-making. We compared 4 different methods of determination of CO in BAV. METHODS: Preoperative transoesophageal echocardiograms of 62 patients with BAV were analysed. CO was measured using either the coaptation centre or the geometric centre of the root. The geometric centre of the root was determined through approximation using a circle or an ellipse, or the midpoint of a line between the centre of the non-fused and the fused sinuses. RESULTS: The 3 different geometric methods led to almost identical results (interclass coefficient 0.98–0.99), with the line segment being the easiest to use. The use of the coaptation centre was associated with the underestimation of commissural angle of up to 30° compared to the geometric centre; the discrepancy was significant and most pronounced for asymmetric BAV (140–160°; P = 0.005). CONCLUSIONS: CO can reproducibly be determined using a line segment between the centre of the non-fused and fused sinuses. The use of the coaptation centre can lead to misleading results, in particular in asymmetric BAVs.Keywords
This publication has 7 references indexed in Scilit:
- (Almost) All Nonstenotic Bicuspid Aortic Valves Should Be Preserved or RepairedSeminars in Thoracic and Cardiovascular Surgery, 2019
- Fluid–Structure Interaction Models of Bicuspid Aortic Valves: The Effects of Nonfused Cusp AnglesJournal of Biomechanical Engineering, 2018
- Two decades of experience with root remodeling and valve repair for bicuspid aortic valvesThe Journal of Thoracic and Cardiovascular Surgery, 2017
- Sinus Plication to Improve Valve Configuration in Bicuspid Aortic Valve Repair—Early ResultsThe Annals of Thoracic Surgery, 2017
- Valve sparing-root replacement with the reimplantation technique to increase the durability of bicuspid aortic valve repairThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic ValveCirculation, 2011
- Congenitally Bicuspid Aortic Valves: A Surgical Pathology Study of 542 Cases (1991 Through 1996) and a Literature Review of 2,715 Additional CasesMayo Clinic Proceedings, 1999