Telemonitoring and Telerehabilitation of Patients with Parkinson’s Disease: Health Technology Assessment of a Novel Wearable Step Counter
- 1 February 2008
- journal article
- research article
- Published by SAGE Publications in Telemedicine and e-Health
- Vol. 14 (1) , 76-83
Abstract
Step counting is an important index of motion in telemonitoring. One of the most diffused wearable systems, designed for this purpose, is the pedometer. The accuracy of commercial pedometers has been reported in the literature. Several limits have been found in many commercial systems both in healthy subjects and in people with disabilities. Furthermore, commercial pedometers lack interoperability. This paper introduces a new wearable system for step counting for telemonitoring applications. This system is based on a wearable device with a force-sensing resistor. It is affixed on the gastrocnemius muscle for monitoring muscular expansion correlated with the gait. The data exchange is assured by the XTR-434H (Aurel, FC, Italy) telemetric system. The proposed gastrocnemius expansion measurement unit (GEMU) was tested on 5 subjects with Parkinson's disease at Level 3 of the Tinetti test of unbalance. Ten repetitions of 500 steps with three different speeds (fast, slow, and normal) were performed. The mean error was <0.5%. Results also showed that GEMU performed better than an accelerometer unit (considered in the literature the best solution for this disability). The study showed that GEMU had a high performance in subjects with Parkinson's disease, causing a high degree of unbalance that confounded motion style. The next phase will be the optimization of GEMU for long-term medical applications at the patient's home.Keywords
This publication has 15 references indexed in Scilit:
- Investigation of fall-risk using a wearable device with accelerometers and rate gyroscopesPhysiological Measurement, 2006
- Physiological motion monitoring: a wearable device and adaptative algorithm for sit-to-stand timing detectionPhysiological Measurement, 2006
- Comparison of three different kinematic sensor assemblies for locomotion studyPhysiological Measurement, 2005
- The Development and Test of a Device for the Reconstruction of 3-D Position and Orientation by Means of a Kinematic Sensor Assembly With Rate Gyroscopes and AccelerometersIEEE Transactions on Biomedical Engineering, 2005
- Accelerometer based calf muscle pump activity monitoringMedical Engineering & Physics, 2005
- An investigation of the effect of electrode size and electrode location on comfort during stimulation of the gastrocnemius muscleMedical Engineering & Physics, 2004
- Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data?IEEE Transactions on Biomedical Engineering, 2003
- Utility of Pedometers for Assessing Physical ActivitySports Medicine, 2002
- Prolonged duration of standing up is an early dopa-sensitive abnormality in Parkinson's diseaseJournal of the Neurological Sciences, 1997
- Detection of static and dynamic activities using uniaxial accelerometersIEEE Transactions on Rehabilitation Engineering, 1996