Time-to-isolation-guided cryoballoon ablation reduces oesophageal and mediastinal alterations detected by endoscopic ultrasound: results of the MADE-PVI trial
Open Access
- 29 May 2019
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 21 (9) , 1325-1333
Abstract
Cryoballoon ablation is safe and efficient for achieving pulmonary vein isolation (PVI) in atrial fibrillation. Structural oesophago-mediastinal lesions, which seem to be associated with an increased risk of the lethal complication of an atrio-oesophageal fistula, have been described. MADE-PVI (Mediastino-oesophageal Alterations Detected by Endosonography after PVI) aimed at evaluating safety of cryoballoon PVI in relation to two different freeze protocols. As time-to-isolation-(TTI)-guided protocol has been reported to be as effective as conventional ‘two freeze protocol’, we hypothesized a TTI-guided protocol causes less oesophago-mediastinal lesions. Seventy consecutive patients were scheduled for cryoballoon (2nd generation) PVI employing either a conventional protocol (n = 35: 2 × 180 s per vein) or a TTI-guided approach (n = 35: TTI + 120 s per vein or 1 × 180 s in case TTI could not be measured). Oesophagogastroduodenoscopy and endoscopic ultrasound, assessing oesophago-mediastinal alterations (e.g. ulceration, oedema) were performed blinded prior and post-ablation. Post-interventional mediastinal oedematous alterations were detected in 70% with a mean diameter of 14 mm (±0.9 mm), while only 15% revealed large mediastinal oedema >20 mm. Oesophageal lesions due to PVI occurred in 5%. Freeze protocols had a distinct impact on oesophago-mediastinal alterations as mean diameter and frequency of large oedema were significantly increased in patients after conventional protocol PVI (17 mm vs. 11 mm; 26% vs. 6%). Furthermore, every oesophageal lesion was detected in patients with conventional protocol (9%). No major complication occurred in either group. The present prospective study demonstrates a significant impact of freeze protocol on oesophago-mediastinal alterations. A TTI-guided protocol reduces mediastino-oesophageal lesions and may reduce short- and long-term complications of cryoballoon PVI.Keywords
Funding Information
- Medtronic (A 1351459)
This publication has 19 references indexed in Scilit:
- Esophagus‐Related Complications During Second‐Generation Cryoballoon Ablation—Insight from Simultaneous Esophageal Temperature Monitoring from 2 Esophageal ProbesJournal of Cardiovascular Electrophysiology, 2016
- Esophageal and Mediastinal Lesions Following Multielectrode Duty-Cycled Radiofrequency Pulmonary Vein Isolation: Simple Equals Safe?Pacing and Clinical Electrophysiology, 2016
- Cryoballoon Versus Open Irrigated Radiofrequency Ablation in Patients With Paroxysmal Atrial FibrillationCirculation, 2015
- Global Survey of Esophageal and Gastric Injury in Atrial Fibrillation AblationJACC, 2015
- Increased Incidence of Esophageal Thermal Lesions Using the Second-Generation 28-mm CryoballoonCirculation: Arrhythmia and Electrophysiology, 2013
- Prophylactic proton pump inhibition after atrial fibrillation ablation: is there any evidence?EP Europace, 2011
- Damage to the Esophagus After Atrial Fibrillation AblationCirculation: Arrhythmia and Electrophysiology, 2010
- Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2010
- The esophageal effects of cryoenergy during cryoablation for atrial fibrillationHeart Rhythm, 2009
- Canine Model of Esophageal Injury and Atrial-Esophageal Fistula After Applications of Forward-Firing High-Intensity Focused Ultrasound and Side-Firing Unfocused Ultrasound in the Left Atrium and Inside the Pulmonary VeinCirculation: Arrhythmia and Electrophysiology, 2009