Digital fault location for parallel double-circuit multi-terminal transmission lines
Authors:
- T. FunabashiTFT. Funabashi
- H. OtoguroHOH. Otoguro
- Y. MizumaYMY. Mizuma
- L. DubeLDL. Dube
- A. AmetaniAAA. Ametani
- 1 April 2000
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 15 (2) , 531-537
Abstract
Two new methods are proposed for fault point location in parallel double-circuit multi-terminal transmission lines by using voltages and currents information from CCVTs and CTs at all terminal. These algorithms take advantage of the fact that the sum of currents flowing into a fault section equals the sum of the currents at all terminals. Algorithm 1 employs an impedance calculation and algorithm 2 employs the current diversion ratio method. Computer simulations are carried out and applications of the proposed methods are discussed. Both algorithms can be applied to all types of fault such as phase-to-ground and phase-to-phase faults. As one equation can be used for all types of fault, classification of fault types and selection of faulted phase are not required. Phase components of the line impedance are used directly, so compensation of unbalanced line impedance is not required.Keywords
This publication has 12 references indexed in Scilit:
- Unsynchronized two-terminal fault location estimationIEEE Transactions on Power Delivery, 1996
- Fault location using digital relay dataIEEE Computer Applications in Power, 1995
- Development of a new fault location system for multi-terminal single transmission linesIEEE Transactions on Power Delivery, 1995
- New technique for the accurate location of earth faults on transmission systemsIEE Proceedings - Generation, Transmission and Distribution, 1995
- Development of a new fault location algorithm for multi-terminal two parallel transmission linesIEEE Transactions on Power Delivery, 1992
- A new fault location technique for two- and three-terminal linesIEEE Transactions on Power Delivery, 1992
- A new fault location algorithm for radial transmission lines with loadsIEEE Transactions on Power Delivery, 1989
- A technique for estimating transmission line fault locations from digital impedance relay measurementsIEEE Transactions on Power Delivery, 1988
- An Accurate Fault Locator With Compensation For Apparent Reactance In The Fault Resistance Resulting From Remore-End InfeedIEEE Transactions on Power Apparatus and Systems, 1985
- Development of a New Type Fault Locator Using the One-Terminal Voltage and Current DataIEEE Transactions on Power Apparatus and Systems, 1982