Validity of combining heart rate and uniaxial acceleration to measure free-living physical activity energy expenditure in young men
- 1 December 2012
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 113 (11) , 1763-1771
Abstract
Combining accelerometry (ACC) with heart rate (HR) monitoring is thought to improve activity energy expenditure (AEE) estimations compared with ACC alone to evaluate the validity of ACC and HR used alone or combined. The purpose of this study was to estimate AEE in free-living conditions compared with doubly labeled water (DLW). Ten-day free-living AEE was measured by a DLW protocol in 35 18- to 55-yr-old men (11 lean active; 12 lean sedentary; 12 overweight sedentary) wearing an Actiheart (combining ACC and HR) and a RT3 accelerometer. AEE was estimated using group or individual calibration of the HR/AEE relationship, based on an exercise-tolerance test. In a subset (n = 21), AEE changes (ΔAEE) were measured after 1 mo of detraining (active subjects) or an 8-wk training (sedentary subjects). Actiheart-combined ACC/HR estimates were more accurate than estimates from HR or ACC alone. Accuracy of the Actiheart group-calibrated ACC/HR estimates was modest [intraclass correlation coefficient (ICC) = 0.62], with no bias but high root mean square error (RMSE) and limits of agreement (LOA). The mean bias of the estimates was reduced by one-third, like RMSE and LOA, by individual calibration (ICC = 0.81). Contrasting with group-calibrated estimates, the Actiheart individual-calibrated ACC/HR estimates explained 40% of the variance of the DLW-ΔAEE (ICC = 0.63). This study supports a good level of agreement between the Actiheart ACC/HR estimates and DLW-measured AEE in lean and overweight men with varying fitness levels. Individual calibration of the HR/AEE relationship is necessary for AEE estimations at an individual level rather than at group scale and for ΔAEE evaluation.Keywords
This publication has 37 references indexed in Scilit:
- Advances in physical activity monitoring and lifestyle interventions in obesity: a reviewInternational Journal of Obesity, 2011
- Comparative Validity of Physical Activity Measures in Older AdultsMedicine & Science in Sports & Exercise, 2011
- Accuracy and validity of a combined heart rate and motion sensor for the measurement of free-living physical activity energy expenditure in adults in CameroonInternational Journal of Epidemiology, 2010
- Improving assessment of daily energy expenditure by identifying types of physical activity with a single accelerometerJournal of Applied Physiology, 2009
- Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activityJournal of Applied Physiology, 2007
- Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-livingEuropean Journal of Applied Physiology, 2005
- Reliability and validity of the combined heart rate and movement sensor ActiheartEuropean Journal of Clinical Nutrition, 2005
- Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditureJournal of Applied Physiology, 2004
- Influence of delayed isotopic equilibration in urine on the accuracy of the 2H2 18O method in the elderlyJournal of Applied Physiology, 2002
- REGRESSION ANALYSISThe Lancet, 1986