Comparison of Oculus Pentacam and Stratus Optical Coherence Tomography for Measurement of Central Corneal Thickness
Authors:
- Osman Melih CeylanOCOsman Melih Ceylan
- Adem TurkATAdem Turk
- Cuneyt ErdurmanCECuneyt Erdurman
- Tarkan MumcuogluTMTarkan Mumcuoglu
- Uzeyir ErdemUEUzeyir Erdem
- Gokcen GokceGGGokcen Gokce
- Selim DagliSDSelim Dagli
- 1 June 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 30 (6) , 670-674
Abstract
Measurement of central corneal thickness (CCT) plays an essential role in the diagnosis and treatment of many ocular diseases. In this study, we aimed to compare the CCT measurements obtained using the Scheimpflug system (Pentacam; Oculus, Inc) with a retinal optical coherence tomography device (Stratus OCT; Carl Zeiss Meditec, Inc) to examine healthy corneas. CCT measurements of 80 eyes belonging to 40 male patients (mean age: 24.48 ± 6.01 years) were evaluated with the Pentacam and the Stratus OCT. The relationship between the CCT values obtained with these 2 devices was examined with a Pearson correlation analysis, a paired t test, and a Bland-Altman analysis. The average CCT value obtained with Pentacam was 546.11 ± 34.15 μm and that obtained with Stratus OCT was 567.76 ± 35.02 μm. Although the average difference between the devices was 21.65 ± 8.59 μm (P < 0.0001), the measurements obtained with both devices were significantly correlated (r = 0.969, P < 0.0001). In Bland-Altman analysis, there was a high consistency between measurements obtained with either Pentacam or Stratus OCT devices. Corneal thickness measurements differ depending on the device used. Corneal thicknesses that have been calculated with Pentacam were lower than the values obtained with Stratus OCT. Both devices used for CCT measurement are easily applied, noninvasive, and effective. However, the devices are not interchangeable. Stratus OCT is not optimal for CCT measurement because of the important limitations of using manual measurements, but it can be used if other measurement devices designed for the purpose are not available.Keywords
This publication has 38 references indexed in Scilit:
- Average 3-Dimensional Models for the Comparison of Orbscan II and Pentacam Pachymetry Maps in Normal CorneasOphthalmology, 2009
- Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence TomographyYonsei Medical Journal, 2009
- Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopiaJournal of Cataract & Refractive Surgery, 2007
- Measuring the cornea: the latest developments in corneal topographyCurrent Opinion in Ophthalmology, 2007
- Measurement of Corneal Swelling Variations without Removal of the Contact Lens during Extended WearInvestigative Ophthalmology & Visual Science, 2007
- Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?British Journal of Ophthalmology, 2007
- Stratus optical coherence tomogram III: A novel, reliable and accurate way to measure corneal thicknessIndian Journal Of Ophthalmology, 2007
- Authors′ replyIndian Journal Of Ophthalmology, 2007
- Central corneal thickness determined with optical coherence tomography in various types of glaucomaBritish Journal of Ophthalmology, 2000
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986