Ti/TiO2 indicator electrodes formed by plasma electrolytic oxidation for potentiometric analysis
- 25 September 2016
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 96 (12) , 1128-1144
Abstract
Ti/TiO2 indicator electrodes were prepared by plasma electrolytic oxidation (PEO) method in the tetraborate electrolyte and were used for potentiometric indication of chemical reactions of different types and for analysis of surface and industrial wastewaters on the example of potentiometric determination of alkalinity and chloride. The electrodes formed at current densities of 0.05, 0.1, 0.15 and 0.2 A/cm2 are different in composition, surface morphology and electroanalytical properties. The electrodes formed at a current density of 0.05 A/cm2 exhibit the highest pH-sensitivity and generate the highest analytical signal at the equivalence point in the acid–base and precipitation titrations. The maximum analytical signal at the equivalence point, exceeding in magnitude the analytical signal, obtained by classical Pt electrode in oxidation–reduction and complexometric titrations generates PEO layers formed at a current density of 0.05 A/cm2 and a platinum-modified nanoparticles. The results of the potentiometric titration of the surface and technogenic waters using as indicator Ti/TiO2 electrodes are comparable with the conventionally used glass electrode (to determine alkalinity) and Ag electrode (to the determine chloride) and the results of visual titration. The advantage of the obtained metal oxide systems is the ability to determine two hydrochemical parameters due to their multifunctionality and opportunity to work with a single electrode. In addition, these sensors offer some analytical characteristics such as sensitivity, good reproducibility, high mechanical stability and a simple preparation procedure.Keywords
This publication has 26 references indexed in Scilit:
- Preparation of ceramic coating on Ti substrate by plasma electrolytic oxidation in different electrolytes and evaluation of its corrosion resistance: Part IIApplied Surface Science, 2012
- Modified sensors based on semiconductor and metallic materials for the determination of cyan- and iodine-containing pesticides by potentiometric titrationJournal of Analytical Chemistry, 2011
- Using of Ti/Co3O4/PbO2/(SnO2+Sb2O3) modified electrode as indicator electrode in potentiometric and conductometric titration in aqueous solutionJournal of Electroanalytical Chemistry, 2011
- Water quality changes of a closed underground coal mine in KoreaEnvironmental Monitoring and Assessment, 2011
- Chemical sensors and their systemsJournal of Analytical Chemistry, 2010
- A pH sensor based on the TiO2 nanotube array modified Ti electrodeElectrochimica Acta, 2010
- Electrochemical SensorsAnalytical Chemistry, 2006
- Molecularly imprinted TiO2 thin film using stable ground-state complex as template as applied to selective electrochemical determination of mercuryTalanta, 2006
- Passive mine water treatment at the former Wheal Jane tin mine, Cornwall: important biogeochemical and microbiological lessonsLand Contamination & Reclamation, 2003
- MOCVD of titanium dioxide on the basis of new precursorsJournal of Non-Crystalline Solids, 2002