A Novel Fabrication Method for Compliant Silicone Phantoms of Arterial Geometry for Use in Particle Image Velocimetry of Haemodynamics
Open Access
- 11 September 2019
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 9 (18) , 3811
Abstract
Cardiovascular diseases (CVDs) are one of the leading causes of death globally. In-vitro measurement of blood flow in compliant arterial phantoms can provide better insight into haemodynamic states and therapeutic procedures. However, current fabrication techniques are not capable of producing thin-walled compliant phantoms of complex shapes. This study presents a new approach for the fabrication of compliant phantoms suitable for optical measurement. Two 1.5× scaled models of the ascending aorta, including the brachiocephalic artery (BCA), were fabricated from silicone elastomer Sylgard-184. The initial phantom used the existing state of the art lost core manufacturing technique with simple end supports, an acrylonitrile butadiene styrene (ABS) additive manufactured male mould and Ebalta-milled female mould. The second phantom was produced with the same method but used more rigid end supports and ABS male and female moulds. The wall thickness consistency and quality of resulting stereoscopic particle image velocimetry (SPIV) were used to verify the fidelity of the phantom for optical measurement and investigation of physiological flow fields. However, the initial phantom had a rough surface that obscured SPIV analysis and had a variable wall thickness (range = 0.815 mm). The second phantom provided clear particle images and had a less variable wall thickness (range = 0.317 mm). The manufacturing method developed is suitable for fast and cost-effective fabrication of different compliant arterial phantom geometries.Keywords
This publication has 48 references indexed in Scilit:
- Optimized Time-Resolved Echo Particle Image Velocimetry– Particle Tracking Velocimetry Measurements Elucidate Blood Flow in Patients With Left Ventricular ThrombusJournal of Biomechanical Engineering, 2018
- Flow features and device‐induced blood trauma in CF‐VADs under a pulsatile blood flow condition: A CFD comparative studyInternational Journal for Numerical Methods in Biomedical Engineering, 2017
- Carotid artery hemodynamics before and after stenting: A patient specific CFD studyComputers & Fluids, 2016
- Application of full field optical studies for pulsatile flow in a carotid artery phantomBiomedical Optics Express, 2015
- Demographic and Epidemiologic Drivers of Global Cardiovascular MortalityNew England Journal of Medicine, 2015
- In Vitro Shear Stress Measurements Using Particle Image Velocimetry in a Family of Carotid Artery Models: Effect of Stenosis Severity, Plaque Eccentricity, and UlcerationPLOS ONE, 2014
- Pulsatile flows and wall-shear stresses in models simulating normal and stenosed aortic archesExperiments in Fluids, 2009
- Three-phase CFD analytical modeling of blood flowMedical Engineering & Physics, 2007
- Reconstruction of blood flow patterns in a human carotid bifurcation: A combined CFD and MRI studyJournal of Magnetic Resonance Imaging, 2000
- A noninvasive method to estimate wall shear rate using ultrasoundUltrasound in Medicine & Biology, 1995