Noninvasive liver-iron measurements with a room-temperature susceptometer
Authors:
- 7 March 2007
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 28 (4) , 349-361
Abstract
Magnetic susceptibility measurements on the liver can quantify iron overload accurately and noninvasively. However, established susceptometer designs, using superconducting quantum interference devices (SQUIDs) that work in liquid helium, have been too expensive for widespread use. This paper presents a less expensive liver susceptometer that works at room temperature. This system uses oscillating magnetic fields, which are produced and detected by copper coils. The coil design cancels the signal from the applied field, eliminating noise from fluctuations of the source-coil current and sensor gain. The coil unit moves toward and away from the patient at 1 Hz, cancelling drifts due to thermal expansion of the coils. Measurements on a water phantom indicated instrumental errors less than 30 microg of iron per gram of wet liver tissue, which is small compared with other errors due to the response of the patient's body. Liver-iron measurements on eight thalassemia patients yielded a correlation coefficient r = 0.98 between the room-temperature susceptometer and an existing SQUID. These results indicate that the fundamental accuracy limits of the room-temperature susceptometer are similar to those of the SQUID.Keywords
This publication has 28 references indexed in Scilit:
- The magnetic susceptibilities of iron deposits in thalassaemic spleen tissueBiochimica et Biophysica Acta (BBA) - Molecular Basis of Disease, 2007
- Non-Invasive Measurement of Iron Overload in the Human BodyIEEE Transactions on Applied Superconductivity, 2006
- Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonanceBlood, 2005
- Evaluation of iron overloadBritish Journal of Haematology, 2004
- An alternating current superconductor susceptometric system to evaluate liver iron overloadReview of Scientific Instruments, 2003
- Noninvasive measurement of iron: report of an NIDDK workshopBlood, 2003
- Iron overload is a determinant of morbidity and mortality in adult patients with sickle cell diseaseSeminars in Hematology, 2001
- Complications following percutaneous liver biopsyJournal of Hepatology, 1986
- Magnetic-Susceptibility Measurement of Human Iron StoresNew England Journal of Medicine, 1982
- Magnetic measurement of human iron storesIEEE Transactions on Magnetics, 1980