The Stability of Corneal Topography in the Post-Blink Interval
Authors:
- Michael J. CollinsMCMichael J. Collins
- D. Robert IskanderDID. Robert Iskander
- Brett DavisBDBrett Davis
- Bernd LingelbachBLBernd Lingelbach
- 1 November 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 20 (8) , 826-833
Abstract
Videokeratoscopes provide a wealth of information about the topography of the ocular surface. Although there have been numerous studies of the accuracy and precision of videokeratoscopes with inanimate test objects, little information exists on their precision (repeatability) for real eyes. To investigate the stability of the ocular surface in the inter-blink period, 10 patients were recruited for videokeratoscopy. Tear break-up time was measured and videokeratographs were acquired immediately post-blink and again at 4, 8, and 12 seconds post-blink. To permit statistical inferences to be drawn from the data, we acquired 24 videokeratographs for each of the four post-blink intervals. The videokeratograph data were interpolated (bilinear) to a common grid, and average and standard deviation (SD) maps were derived for each post-blink condition. t Tests were used to test the significance of changes observed in the topography. The instantaneous power SD maps showed increasing variation toward the periphery, with most maps showing less than ±0.5 diopters (D) of SD in the central 4 to 5 mm and variation in the periphery often reaching more than ±1 D SD at the edge of an 8-mm diameter. When the 4-, 8-, and 12-second average maps were subtracted from the average map acquired immediately after blinking, regions of statistically significant (p < 0.001) change were apparent in the upper and lower regions of the maps. The upper and lower bands of change were found to correlate with the natural position of the patients' lid margins. For normal eyes, the central regions of videokeratographs show high stability in the inter-blink period. However, the upper and lower edges of 8-mm diameter maps show statistically significant variability, which appears to be related to the effects of eyelid pressure.Keywords
This publication has 31 references indexed in Scilit:
- The Accuracy and Precision Performance of Four Videokeratoscopes in Measuring Test SurfacesOptometry and Vision Science, 2000
- Accuracy of the Tomey Topographic Modeling System in Measuring Surface Elevations of Asymmetric ObjectsOptometry and Vision Science, 1999
- The reproducibility of videokeratoscope measurements as applied to the human corneaContact Lens and Anterior Eye, 1999
- Comparison of Three Computerized Videokeratoscopy Systems with KeratometryCornea, 1998
- Evaluation of the EyeSys Model II Computerized Videokeratoscope. Part II: The Repeatability and Accuracy in Measuring Convex Aspheric SurfacesOptometry and Vision Science, 1998
- Comparison of Repeat Videokeratography: Repeatability and AccuracyOptometry and Vision Science, 1998
- Comparative study of the elevation topography of complex shapesJournal of Cataract & Refractive Surgery, 1998
- Corneal Geometry Reconstruction with the Keratron VideokeratographerOptometry and Vision Science, 1997
- Keratometric variation: the influence of a fluid layerOphthalmic and Physiological Optics, 1996
- Accuracy and Precision of the Corneal Analysis System and the Topographic Modeling SystemCornea, 1992