Determination of non-metals via molecular absorption using high-resolution continuum source absorption spectrometry and graphite furnace atomization
Authors:
- 22 September 2006
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 21 (11) , 1314-1320
Abstract
This work describes investigations on the determination of the non-metals fluorine, chlorine, sulfur and phosphorus in a graphite furnace atomizer using high-resolution continuum source absorption spectrometry. With this technique, the general problem of limited accessibility to the non-metal resonance lines, all located in the vacuum ultraviolet wavelength region, could be avoided by evaluation of narrow-band molecular absorption in the ultraviolet spectral region. The absorption originates from diatomic molecules produced under certain conditions in the graphite atomizer in the presence of the element in question. In detail, an excess of the metals gallium and aluminium was used to convert fluorine and chlorine to their molecular forms GaF and AlCl, respectively. In a similar manner, sulfur could be converted to CS and phosphorus to PO molecules. For all species, narrow spectral structures, belonging to specific band heads or individual rotational lines, could be found at well-accessible wavelengths between 211 and 261 nm. Using these absorption structures, analytical parameters were evaluated for the determination of the four non-metals. The obtained values for the characteristic masses and the limits of detection are as follows: 13 pg and 9 pg for fluorine; 300 pg and 70 pg for chlorine; 12 ng and 2.3 ng for sulfur; 4.4 ng and 0.9 ng for phosphorus. All methods developed were confirmed by measurements on certified reference materials. In comparison to previous investigations with an air–acetylene flame system, an improvement of up to three orders of magnitude in the limits of detection was achieved.Keywords
This publication has 35 references indexed in Scilit:
- Determination of halogens via molecules in the air–acetylene flame using high-resolution continuum source absorption spectrometry, Part II: ChlorineSpectrochimica Acta Part B: Atomic Spectroscopy, 2006
- Determination of halogens via molecules in the air–acetylene flame using high-resolution continuum source absorption spectrometry: Part I. FluorineSpectrochimica Acta Part B: Atomic Spectroscopy, 2006
- Determination of sulfur by molecular absorption of carbon monosulfide using a high-resolution continuum source absorption spectrometer and an air-acetylene flameSpectrochimica Acta Part B: Atomic Spectroscopy, 2006
- Determination of phosphorus by molecular absorption of phosphorus monoxide using a high-resolution continuum source absorption spectrometer and an air–acetylene flameJournal of Analytical Atomic Spectrometry, 2005
- Determination of fluoride in drinking water and sea water by aluminium monofluoride molecular absorption spectrometry using an electrothermal graphite furnaceThe Analyst, 1988
- Molecular absorption spectrometry (MAS) by electrothermal evaporation in a graphite furnace—XIII Determination of traces of fluoride by mas of AlF after liquid-liquid extraction of fluoride with triphenylantimony(V) dihydroxideTalanta, 1985
- Effect of matrix modifier and furnace material on the determination of traces of fluoride by electrothermal molecular absorption spectrometry of aluminum monofluorideAnalytica Chimica Acta, 1985
- Subnanogram fluorine determination by aluminum monofluoride molecular absorption spectrometryAnalytical Chemistry, 1977
- A micro method for direct determination of ionic fluoride in body fluids with the hanging drop fluoride electrodeClinica Chimica Acta, 1975
- The Determination of Fluoride in Blood SerumCaries Research, 1968