Impact of location and deadband on energy performance of nano aerogel glazing for office building in Saudi Arabia
- 9 December 2019
- journal article
- research article
- Published by Taylor & Francis in Building Research & Information
- Vol. 48 (6) , 645-658
Abstract
The present study has focused on the impact of location and deadband (range of thermostat setpoints for cooling and heating) on the energy performance and economics of nano granular silica aerogel (nanogel) glazing in a multi-storey office building, by considering 26 climatic locations of Saudi Arabia. The selected cities were classified according to the cooling degree days (CDD) and outdoor dry bulb temperature (DBT), as warm, moderately hot, hot, and very hot, and the results were generalized with respect to these climatic zones. The building model was built in Autodesk Revit (2015), and the energy simulation was performed by Ecotect (2011) in two cases: (i) insulated wall and roof, and DG window and (ii) insulated wall and roof, and nanogel glazing. The results show that the location and deadband have crucial impact on the energy performance and economic viability of nanogel glazing. The energy-saving potential and payback period of replacing DG window by nanogel glazing are attractive for cities with higher DBTs and CDD, compared to those with lower DBT and CDD. For all the climatic zones studied, the benefit of replacing DG window by nanogel glazing could be achieved for a specific deadband of 20–24°C.Keywords
This publication has 53 references indexed in Scilit:
- Fenestration of today and tomorrow: A state-of-the-art review and future research opportunitiesSolar Energy Materials and Solar Cells, 2012
- Design an Optimum Pattern of Orientation in Residential Complexes by Analyzing the Level of Energy Consumption (Case Study: Maskan Mehr Complexes, Tehran, Iran)Procedia Engineering, 2011
- Passive building energy savings: A review of building envelope componentsRenewable and Sustainable Energy Reviews, 2011
- Improving the thermal performance of single-glazed windows using translucent granular aerogelInternational Journal of Sustainable Engineering, 2011
- Thermal zoning and interzonal airflow in the design and simulation of solar houses: a sensitivity analysisJournal of Building Performance Simulation, 2011
- Contrasting the capabilities of building energy performance simulation programsBuilding and Environment, 2008
- Radiocarbon and DNA evidence for a pre-Columbian introduction of Polynesian chickens to ChileProceedings of the National Academy of Sciences, 2007
- Silica aerogel granulate material for thermal insulation and daylightingSolar Energy, 2005
- Database for building energy prediction in Saudi ArabiaEnergy Conversion and Management, 2002
- Highly insulating aerogel glazing for solar energy usageSolar Energy, 2002