Biomechanical Evaluation of an Anatomically Correct All-Ceramic Tooth-Crown System Configuration: Core Layer Multivariate Analysis Incorporating Clinically Relevant Variables
- 24 March 2010
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 132 (5) , 051001
Abstract
In a crown system, core fracture requires replacement of the restoration. Understanding maximum principal stress concentration in the veneered core of a tooth-crown system as a function of variations in clinically relevant parameters is crucial in the rational design of crown systems. This study evaluated the main and interacting effects of a set of clinical variables on the maximum principal stress (MPS) in the core of an anatomically correct veneer-core-cement-tooth model. A 3D CAD model of a mandibular first molar crown was generated; tooth preparation was modeled by reducing the proximal walls by 1.5 mm and the occlusal surface by 2.0 mm. A cemented veneered core crown was modeled on the preparation. This “crown system” permitted finite element model investigation of the main and interacting effects of proximal wall height reduction, core material, core thickness, cement modulus, cement thickness, and load position on the maximum stress distribution in a factorial design. Analysis of variance was used to identify the main and interacting influences on the level of MPS in the crown core. Statistical significance was set at p<0.05. MPS levels varied as a function of two-way interactions between the following: core thickness and load position; cement thickness and load position; cement modulus and load position; cement thickness and core thickness; and cement thickness and cement modulus; and also three-way interactions among the load position, core material, and proximal wall height reduction, and among the core thickness, cement thickness, and cement modulus. MPS in the crown-tooth system is influenced by the design parameters and also by the interaction among them. Hence, while the geometry of molar crowns is complex, these analyses identify the factors that influence MPS and suggest levels that will minimize the core MPS in future studies of crown design.Keywords
This publication has 29 references indexed in Scilit:
- Design features of a three-dimensional molar crown and related maximum principal stress. A finite element model studyDental Materials, 2010
- Fatigue testing of two porcelain–zirconia all-ceramic crown systemsDental Materials, 2009
- A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practiceJournal of Dentistry, 2009
- Off-axis sliding contact reliability and failure modes of veneered alumina and zirconiaDental Materials, 2009
- Laboratory Simulation of Y-TZP All-ceramic Crown Clinical FailuresJournal of Dental Research, 2009
- An overview of zirconia ceramics: Basic properties and clinical applicationsJournal of Dentistry, 2007
- Recent Advances in Materials for All-Ceramic RestorationsDental Clinics of North America, 2007
- Effect of water storage time and composite cement thickness on fatigue of a glass‐ceramic trilayer systemJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Comparison of the performance on prosthodontic criteria of several alternative alloys used for fixed crown and partial denture restorations: Department of Veterans Affairs Cooperative Studies Project 147The Journal of Prosthetic Dentistry, 1993
- Three-dimensional finite element analysis of glass-ceramic dental crownsJournal of Biomechanics, 1990