Abstract
We develop a multi-pulse test for dynamic interface trap characterization in lateral double-diffused MOSFET (LDMOS) devices. By extracting the gate-to-drain charge $(Q_{\mathrm { GD}})$ during Miller plateau, the proposed method indicates the quantitative evaluation of the interface trap charge $(Q_{\mathrm { it}})$ in the n-drift region under switching conditions. Experimental results reveal that increased interface trap density $(D_{\mathrm { it}})$ leads to prolonged switching transitions and elevated $Q_{\mathrm { GD}}$ . Besides, increasing the number of pulses enables the extraction of multiple $Q_{\mathrm { it}}$ values and their corresponding carrier capture time distributions. Furthermore, varying the test pulse amplitude facilitates selective probing of $D_{\mathrm { it}}$ at different trap energy levels $(E_{\mathrm { T}})$ . The proposed fast dynamic evaluation technique demonstrates significant potential for interface trap analysis in the n-drift region of power MOSFET devices and provides a practical tool for their reliability assessment.