Experimental Methods for Measuring the Efficiency of a Molten Salt Central Receiver
Open Access
- 2 February 2024
- journal article
- research article
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 1
Abstract
In this work, two different methods for measuring the efficiency of central receivers are analyzed by the case of the High Performance Molten Salt II Project (HPMS-II): the continuous power-on method, and the semi-analytical method. The main difference between the two methods is the procedure to calculate the thermal losses of the receiver: on the one hand, the continuous power-on method calculates the thermal losses from the measurement of the absorbed power by the molten salt for different measured incident powers on the receiver. Here, it is assumed that the thermal losses are independent of the incident power if the molten salt temperature is kept constant. On the other hand, the semi-analytical method calculates the thermal losses as the sum of convective and radiative losses, calculated directly from the Newton and Stefan-Boltzmann equations by measuring the temperature of the tube surface, the ambient temperature, and the wind speed. Therefore, the calculation of the thermal losses is independent from one method to another. The procedure of applying these methods during the experimental test campaign of the HPMS-II receiver is detailed in this paper. Additionally, an uncertainty analysis of both methods is conducted to determine the uncertainty expected for the receiver efficiency measurements.Keywords
Funding Information
- Ministerio de Ciencia e Innovación (CAS21/00519)
- Ministerium für Wirtschaft, Innovation, Digitalisierung und Energie des Landes Nordrhein-Westfalen (PRO 0071)
- Bundesministerium für Wirtschaft und Energie (0324327A)
This publication has 12 references indexed in Scilit:
- Proof of concept: Real-time flux density monitoring system on external tube receivers for optimized solar field operationAIP Conference Proceedings, 2023
- Basic engineering of a high performance molten salt tower receiver system2022
- A practical method to evaluate the thermal efficiency of solar molten salt receiversApplied Thermal Engineering, 2021
- Flux density measurement for industrial-scale solar power towers using the reflection off the absorber2019
- Efficiency determination of tubular solar receivers in central receiver systemsSolar Energy, 2016
- Techniques to Measure Solar Flux Density Distribution on Large-Scale ReceiversJournal of Solar Energy Engineering, 2014
- Review of thermal loss evaluations of solar central receivers1986
- Experimental, Variable Properties Natural Convection From a Large, Vertical, Flat SurfaceJournal of Heat Transfer, 1985
- Estimating convective energy losses from solar central receivers1984
- Heat Transfer and Friction in Turbulent Pipe Flow with Variable Physical Properties1970