Sliding electrical contact performance of electromagnetic

Authors:
  • 徐伟徐伟东XuWeidong
    徐伟东XuWeidong
  • 袁伟袁伟群YuanWeiqun
    袁伟群YuanWeiqun
  • 陈允陈允ChenYun
    陈允ChenYun
  • 戴艺戴艺波DaiYibo
    戴艺波DaiYibo
  • 周媛周媛ZhouYuan
    周媛ZhouYuan
  • 杨丹杨丹YangDan
    杨丹YangDan
  • 严萍严萍YanPing
    严萍YanPing
  • 李军李军LiJun
    李军LiJun

Abstract
The high speed sliding contact is between the armature and the rails in the electromagnetic launcher experiments. The contact performance can be influenced by the frictional heating and current joule heating, and the influence is more evident in the rapid fire mode due to the rail temperature rise. This paper discusses the contact performance with the sliding contact resistance. In the experiments, two 5-g armatures are launched with the speed of 1 000 m/s, and frequency of 166 Hz. The effect on the contact resistance of the temperature rise is calculated approximately. The results show that the contact resistance of the second armature is higher than that of the first armature with the temperature rise. In addition, thermal management should be adopted in the multi-armature launching in rapid fire mode.