Characterization of a High Throughput Approach for Large Scale Retention Measurement in Liquid Chromatography
Authors:
- Trevor KempenTKTrevor Kempen
- Tina DahlseidTDTina Dahlseid
- Thomas LauerTLThomas Lauer
- Alexandru FloreaAFAlexandru Florea
- Isabella AaseIAIsabella Aase
- Nathan Cole-DaiNCNathan Cole-Dai
- Simerjit KaurSKSimerjit Kaur
- Caroline SouthworthCSCaroline Southworth
- Kathleen GrubeKGKathleen Grube
- Jos BhandariJBJos Bhandari
- Maria SylvesterMSMaria Sylvester
- Ryan SchimekRSRyan Schimek
Preprint
- 26 January 2023
- preprint
- Published by American Chemical Society (ACS) in ChemRxiv
Abstract
Many contemporary challenges in liquid chromatography - such as the need for “smarter” method development tools, and deeper understanding of chromatographic phenomena - could be addressed more efficiently and effectively with larger volumes of experimental retention data than we have been accustomed to historically. The paucity of publicly accessible, high-quality measurements has been due, at least in large part, to the high cost in time and resources associated with traditional retention measurement approaches. Recently we described an approach to improve the throughput of such measurements by using very short columns (typically 5 mm), while maintaining measurement accuracy. In this paper we present a perspective on the characteristics of results obtained using this approach using a dataset containing about 13,000 retention measurements, and describe an approach to sample introduction that improves upon the prior work. The dataset is comprised of results for 35 different small molecules, nine different stationary phases, and several mobile phase compositions for each analyte/phase combination. During the acquisition of these data, we have interspersed repeated measurements of a small number of compounds for quality control purposes. The data from these measurements not only enable detection of “out of control” measurements, but also assessment of the repeatability and reproducibility of retention measurements over time. For retention factors greater than 1, the mean relative standard deviation (RSD) of replicate (typically n=5) measurements is 0.4%, and the standard deviation of RSDs is 0.4%. Most differences between selectivity values measured six months apart for 15 non-ionogenic compounds were in the range of +/- 1%, indicating good reproducibility. A critically important observation from these analyses is that selectivity (defined here as retention of a given analyte relative to the retention of a reference compound; kx/kref) is a much more consistent measure of retention over time (months) compared to the retention factor alone. While this work and dataset also highlights the importance of stationary phase stability over time for achieving reliable retention measurements, we are nevertheless optimistic that this approach will enable the compilation of large databases (>> 10,000 measurements) of retention values over long time periods (years), which can in turn be leveraged to address some of the most important contemporary challenges in liquid chromatography. All of the data discussed in the manuscript are provided as Supplemental Information.Keywords
All Related Versions
This publication has 11 references indexed in Scilit:
- An approach to high throughput measurement of accurate retention data in liquid chromatographyJournal of Chromatography A, 2022
- A comprehensive study on the phenomenon of total breakthrough in liquid chromatographyJournal of Chromatography A, 2021
- In Silico Multifactorial Modeling for Streamlined Development and Optimization of Two-Dimensional Liquid ChromatographyAnalytical Chemistry, 2021
- Improvements in the predictive accuracy of the hydrophobic subtraction model of reversed-phase selectivityJournal of Chromatography A, 2021
- Recent applications of retention modelling in liquid chromatographyJournal of Separation Science, 2020
- A Novel Multi-model Data-Driven Ensemble Technique for the Prediction of Retention Factor in HPLC Method DevelopmentChromatographia, 2020
- Mismatch between sample diluent and eluent: Maintaining integrity of gradient peaks using in silico approachesJournal of Chromatography A, 2019
- Evaluation of three temperature- and mobile phase-dependent retention models for reversed-phase liquid chromatographic retention and apparent retention enthalpyJournal of Chromatography A, 2019
- Simulation of elution profiles in liquid chromatography − II: Investigation of injection volume overload under gradient elution conditions applied to second dimension separations in two-dimensional liquid chromatographyJournal of Chromatography A, 2017
- Simulation of elution profiles in liquid chromatographyI: Gradient elution conditions, and with mismatched injection and mobile phase solventsJournal of Chromatography A, 2016