ASSESSMENT OF ORGAN ABSORBED DOSES AND ESTIMATION OF EFFECTIVE DOSES FROM PEDIATRIC ANTHROPOMORPHIC PHANTOM MEASUREMENTS FOR MULTI-DETECTOR ROW CT WITH AND WITHOUT AUTOMATIC EXPOSURE CONTROL
Authors:
- Hervé J. BrisseHBHervé J. Brisse
- Magalie RobilliardMRMagalie Robilliard
- Alexia SavignoniASAlexia Savignoni
- Noelle PierratNPNoelle Pierrat
- Geneviève GaboriaudGGGeneviève Gaboriaud
- Yann De RyckeYRYann De Rycke
- Sylvia NeuenschwanderSNSylvia Neuenschwander
- Bernard AubertBABernard Aubert
- Jean-Claude RosenwaldJRJean-Claude Rosenwald
- 1 October 2009
- journal article
- Published by Wolters Kluwer Health in Health Physics
- Vol. 97 (4) , 303-314
Abstract
This study was designed to measure organ absorbed doses from multi-detector row computed tomography (MDCT) on pediatric anthropomorphic phantoms, calculate the corresponding effective doses, and assess the influence of automatic exposure control (AEC) in terms of organ dose variations. Four anthropomorphic phantoms (phantoms represent the equivalent of a newborn, 1-, 5-, and 10-y-old child) were scanned with a four-channel MDCT coupled with a z-axis-based AEC system. Two CT torso protocols were compared: a first protocol without AEC and constant tube current-time product and a second protocol with AEC using age-adjusted noise indices. Organ absorbed doses were monitored by thermoluminescent dosimeters (LiF: Mg, Cu, P). Effective doses were calculated according to the tissue weighting factors of the International Commission on Radiological Protection (ICRP Publication 103). For fixed mA acquisitions, organ doses normalized to the volume CT dose index in a 16-cm head phantom (CTDIvol16) ranged from 0.6 to 1.5 and effective doses ranged from 8.4 to 13.5 mSv. For the newborn-equivalent phantom, the AEC-modulated scan showed almost no significant dose variation compared to the fixed mA scan. For the 1-, 5- and 10-y equivalent phantoms, the use of AEC induced a significant dose decrease on chest organs (ranging from 61 to 31% for thyroid, 37 to 21% for lung, 34 to 17% for esophagus, and 39 to 10% for breast). However, AEC also induced a significant dose increase (ranging from 28 to 48% for salivary glands, 22 to 51% for bladder, and 24 to 70% for ovaries) related to the high density of skull base and pelvic bones. These dose increases should be considered before using AEC as a dose optimization tool in children.Keywords
This publication has 54 references indexed in Scilit:
- Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image qualityMedical Physics, 2008
- Population exposure to ionizing radiation from medical examinations in FranceBritish Journal of Radiology, 2008
- Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: Experimental assessment on pediatric phantomsMedical Physics, 2007
- Angular on‐line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reductionMedical Physics, 2007
- Organ and effective doses in newborn patients during helical multislice computed tomography examinationPhysics in Medicine & Biology, 2006
- National Conference on Dose Reduction in CT, with an Emphasis on Pediatric PatientsAmerican Journal of Roentgenology, 2003
- CT-Expositionspraxis in der Bundesrepublik DeutschlandRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2001
- Radiation doses to infants and adults undergoing head CT examinationsMedical Physics, 2001
- CT scanning: patterns of use and doseJournal of Radiological Protection, 2000
- Active bone marrow distribution as a function of age in humansPhysics in Medicine & Biology, 1981