Abstract
This paper proposes two indirect model predictive control techniques with input filter resonance mitigation operating at fixed switching frequency. These techniques address the main issues of the implementation of model predictive control in a direct matrix converter, namely the high computational cost, the adequate selection of weighting factors and the variable switching frequency which could produce resonances in the input filter. The techniques are based on the fictitious dc-link concept, which has been used in the past for the classical modulation and control techniques of the direct matrix converter. Simulated results confirm the feasibility of the proposal demonstrating that it is an alternative to classical predictive control strategies for the direct matrix converter.

This publication has 14 references indexed in Scilit: