Abstract
OBJECTIVE: Traditionally, stent-assisted coiling and balloon remodeling have been the primary endovascular treatments for wide-necked intracranial aneurysms with complex morphologies. PulseRider is an aneurysm neck reconstruction device that provides parent vessel protection for aneurysm coiling. The objective of this study was to report early postmarket results with the PulseRider device. METHODS: This study was a prospective registry of patients treated with PulseRider at 13 American neurointerventional centers following FDA approval of this device. Data collected included clinical presentation, aneurysm characteristics, treatment details, and perioperative events. Follow-up data included degree of aneurysm occlusion and delayed (> 30 days after the procedure) complications. RESULTS: A total of 54 aneurysms were treated, with the same number of PulseRider devices, across 13 centers. Fourteen cases were in off-label locations (7 anterior communicating artery, 6 middle cerebral artery, and 1 A 1 segment anterior cerebral artery aneurysms). The average dome/neck ratio was 1.2. Technical success was achieved in 52 cases (96.2%). Major complications included the following: 3 procedure-related posterior cerebral artery strokes, a device-related intraoperative aneurysm rupture, and a delayed device thrombosis. Immediately postoperative Raymond-Roy occlusion classification (RROC) class 1 was achieved in 21 cases (40.3%), class 2 in 15 (28.8%), and class 3 in 16 cases (30.7%). Additional devices were used in 3 aneurysms. For those patients with 3- or 6-month angiographic follow-up (28 patients), 18 aneurysms (64.2%) were RROC class 1 and 8 (28.5%) were RROC class 2. CONCLUSIONS: PulseRider is being used in both on- and off-label cases following FDA approval. The clinical and radiographic outcomes are comparable in real-world experience to the outcomes observed in earlier studies. Further experience is needed with the device to determine its role in the neurointerventionalist’s armamentarium, especially with regard to its off-label use.Keywords
This publication has 16 references indexed in Scilit:
- How safe and effective are existing treatments for wide-necked bifurcation aneurysms? Literature-based objective performance criteria for safety and effectivenessJournal of NeuroInterventional Surgery, 2017
- PulseRider-assisted treatment of wide-necked intracranial bifurcation aneurysms: safety and feasibility studyJournal of Neurosurgery, 2017
- Results of the ANSWER Trial Using the PulseRider for the Treatment of Broad-Necked, Bifurcation AneurysmsNeurosurgery, 2017
- Tourniquet parent artery occlusion after flow diversionJournal of NeuroInterventional Surgery, 2017
- PulseRider for Treatment of Wide-Neck Bifurcation Intracranial Aneurysms: 6-Month ResultsWorld Neurosurgery, 2017
- PulseRider Stent-Assisted Coiling of Wide-Neck Bifurcation Aneurysms: Periprocedural Results in an International SeriesAmerican Journal of Neuroradiology, 2015
- Republished: Treatment of wide-necked basilar tip aneurysm not amenable to Y-stenting using the PulseRider deviceJournal of NeuroInterventional Surgery, 2015
- Initial experience with the PulseRider for the treatment of bifurcation aneurysms: report of first three cases in the USAJournal of NeuroInterventional Surgery, 2015
- Waffle‐Cone Technique Using Solitaire AB Stent for Endovascular Treatment of Complex and Wide‐Necked Bifurcation Cerebral AneurysmsJournal of Neuroimaging, 2014
- Stent-Associated Flow Remodeling Causes Further Occlusion of Incompletely Coiled AneurysmsNeurosurgery, 2011