Effects of Different Abutment Connection Designs on the Stress Distribution Around Five Different Implants: A 3-Dimensional Finite Element Analysis
- 1 October 2012
- journal article
- research article
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 38 (S1) , 491-496
Abstract
The stability of the bone-implant interface is required for the long-term favorable clinical outcome of implant-supported prosthetic rehabilitation. The implant failures that occur after the functional loading are mainly related to biomechanical factors. Micro movements and vibrations due to occlusal forces can lead to mechanical complications such as loosening of the screw and fractures of the abutment or implants. The aim of this study was to investigate the strain distributions in the connection areas of different implant-abutment connection systems under similar loading conditions. Five different implant-abutment connection designs from 5 different manufacturers were evaluated in this study. The investigation was performed with software using the finite element method. The geometrical modeling of the implant systems was done with CATIA virtual design software. The MSC NASTRAN solver and PATRAN postprocessing program were used to perform the linear static solution. According to the analysis, the implant-abutment connection system with external hexagonal connection showed the highest strain values, and the internal hexagonal implant-abutment connection system showed the lowest strain values. Conical + internal hexagonal and screw-in implant abutment connection interface is more successful than other systems in cases with increased vertical dimension, particularly in the posterior region.Keywords
This publication has 15 references indexed in Scilit:
- Evaluation of design parameters of osseointegrated dental implants using finite element analysisJournal of Oral Rehabilitation, 2002
- Application of finite element analysis in implant dentistry: A review of the literatureThe Journal of Prosthetic Dentistry, 2001
- Mechanical complications of dental implantsClinical Oral Implants Research, 2000
- Simultaneous force measurements in 3 dimensions on oral endosseous implants in vitro and in vivo. A methodological study.Clinical Oral Implants Research, 1996
- In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implantsClinical Oral Implants Research, 1996
- A Three‐Dimensional Finite Element Stress Analysis of Angled Abutments for an Implant Placed in the Anterior MaxillaJournal of Prosthodontics, 1995
- On clinical loading of osseointegrated implants. A methodological and clinical study.Clinical Oral Implants Research, 1993
- A three-dimensional mathematical model of the human masticatory system predicting maximum possible bite forcesJournal of Biomechanics, 1988
- Limits of human bite strengthThe Journal of Prosthetic Dentistry, 1986
- Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in ManActa Orthopaedica, 1981