Behavior of water droplets on silicone rubber sheet under AC voltage application
Authors:
- M. IwataniMIM. Iwatani
- M. NagataMNM. Nagata
- K. NaitoKNK. Naito
- K. KondoKKK. Kondo
- S. ItoSIS. Ito
- 27 November 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 96-99
Abstract
This paper describes the investigation results of behavior of water droplets on clean/contaminated silicone rubber sheet under ac voltage application. With increase of applied voltage, droplets vibrated first, they were then extended to the direction of applied electric field and finally flashover bridging water droplets occurred. Effect of time lapse after contamination was also studied.Keywords
This publication has 3 references indexed in Scilit:
- Assessment of basic contamination withstand voltage characteristics of polymer insulatorsIEEE Transactions on Power Delivery, 1996
- Flashover mechanism of silicone rubber insulators used for outdoor insulation-IIEEE Transactions on Power Delivery, 1995
- The mechanism of the contamination of porcelain insulatorsJournal of the Institution of Electrical Engineers - Part I: General, 1944