Case Study on the Design of Retrofit Strategies for Corroded Marine Bridge Pile Caps

Authors:
  • BWBaldessar Warmling
    Baldessar Warmling
  • GMGean Marcos
    Gean Marcos
  • SFSantos Filho
    Santos Filho
  • MLMauro Lacerda
    Mauro Lacerda
  • LSLacerda Santos
    Lacerda Santos
  • APAdriana De Paula
    Adriana De Paula
  • ASAndrigo Savegnago
    Andrigo Savegnago

Abstract
This study investigates repair strategies for the pile caps of a bridge exhibiting significant degradation on the bottom face due to the marine environment. A Finite Element Model (FEM) is developed to calculate the force reactions within the pile caps and perform a three-dimensional stress analysis. The FEM model serves as the basis for a strut-and-tie analysis to compare the existing reinforcement with the required reinforcement. Based on the analysis, two types of necessary works are established: strengthening and retrofitting. Strengthening involves inserting a prestressed beam at each side of the pile caps to confine the concrete and act as a ring under ultimate loads. Retrofitting focuses on repairing the bottom face using a methodology that avoids removing all the rust from the rebar to prevent undermining the structure.

This publication has 2 references indexed in Scilit: