Impact of Fouling on Flow-Induced Vibration Characteristics in Fluid-Conveying Pipelines
Open Access
- 20 October 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 4, 6631-6644
Abstract
This paper has addressed the common monitoring problems in petrochemical companies, which are caused by fouling and clogging in the circulating water heat exchangers, and has introduced techniques to monitor the heat exchanger's wall vibrations for early failure detection. Due to the difficulties encountered in simulation caused by the large number of tubes inside the heat exchanger, such monitoring methods are discussed by studying the fouling of a fluid-conveying pipeline. ANSYS was used to establish the normal and fouling models of a fluid-conveying pipeline so as to analyze the changing rules of various parameters that are influenced by different inlet velocities. These parameters include flow velocity, direction, pipeline wall load, wall displacement, and the acceleration of fluid domain in a fluid-conveying pipeline. It is shown that, as the inlet velocity and fouling severity continuously increase, the wall load and the vibration acceleration increase as well, leading variations in wall vibration signals. This paper conducts extensive experiments by using straight pipes to compare the results from simulation with those from the normal fluid-conveying pipelines under the same working conditions. By such comparison, the efficacy of the simulation model has been demonstrated.Keywords
Funding Information
- National Natural Science Foundation of China (61401107, 21576102)
- International and Hong Kong, Macao, and Taiwan collaborative innovation platform and major international cooperation projects of colleges in Guangdong Province (2015KGJHZ026)
- Natural Science Foundation of Guangdong Province (2016A030307029)
- Open Fund of Maoming Study and Development Center of Petrochemical Corrosion and Safety Engineering (201509A01)
- Open Fund of Guangdong Provincial Key Laboratory of Petrochemical Equipment Fault Diagnosis (GDUPTLAB201605)
- Guangdong University of Petrochemical Technology through Internal Project (2012RC106)
This publication has 9 references indexed in Scilit:
- An Experimental Study of Clogging Fault Diagnosis in Heat Exchangers Based on Vibration SignalsIEEE Access, 2016
- Numerical investigation of heat transfer and fluid flow in plate heat exchanger using nanofluidsInternational Journal of Thermal Sciences, 2014
- Effects of Shape and Quantity of Helical Baffle on the Shell-side Heat Transfer and Flow Performance of Heat ExchangersChinese Journal of Chemical Engineering, 2014
- Numerical modeling of finned heat exchangersApplied Thermal Engineering, 2013
- Methods for detection and cleaning of fouling in pipelines2012
- Hammer impact test applied for fouling detection in pipelinesSba: Controle & Automação Sociedade Brasileira de Automatica, 2011
- Non-Invasive Fast Detection of Internal Fouling Layers in Tubes and Ducts by Acoustic Vibration AnalysisIEEE Transactions on Instrumentation and Measurement, 2008
- Fouling Detection based on Vibration Analysis with the Hammer Impact Test2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007, 2007
- Development of turbulence models for shear flows by a double expansion techniquePhysics of Fluids A: Fluid Dynamics, 1992